Chromatography Columns 2013+ - page 114

57
GCCOLUMNS |
GENERALPURPOSECOLUMNS
Rt®-2330, Rt®-2560
similar
phases
DB-23, HP-23, SP-2330, SP-2380
similar
phases
SPB-2560, HP-88, Silar 10C, CP-Sil 88FAME,
CP-Sil 88
NLEAFAMEs resolvedonanRt®-2560column.
Column:
Rt
®
-2560, 100m, 0.25mm ID,
0.20µm (cat.# 13199)
Sample:
NLEA FAMEMix (cat.# 35078),
30mg/mL total FAMEs in
methylene chloride
Inj.:
1.0µL split (split ratio 100:1),
4mm inlet liner (cat.# 20814)
Inj. temp.:
225°C
Carrier gas:
hydrogen, constant flow
Flow rate:
1.2mL/min.
Oven temp.:
100°C (4min. hold) to 240°C
@ 3°C/min. (10min. hold)
Det.:
FID@ 250°C
1. C4:0 methyl butyrate
2. C6:0 methyl hexanoate
3. C8:0 methyl octanoate
4. C10:0 methyl decanoate
5. C11:0 methyl undecanoate
6. C12:0 methyl laurate
7. C13:0 methyl tridecanoate
8. C14:0 methyl myristate
9. C14:1 methyl myristoleate (
cis
-9)
10. C15:0 methyl pentadecanoate
11. C16:0 methyl palmitate
12. C16:1 methyl palmitoleate (
cis
-9)
13. C17:0 methyl heptadecanoate
14. C18:0 methyl stearate
15. C18:1 methyl elaidate (
trans
-9)
16. C18:1 methyl oleate (
cis
-9)
17. C18:2 methyl linoelaidate (
trans
-9,12)
18. C18:2 methyl linoleate (
cis
-9,12)
19. C20:0 methyl arachidate
20. C20:1 methyl eicosenoate (
cis
-11)
21. C18:3 methyl linolenate (
cis
-9,12,15)
22. C22:0 methyl behenate
23. C22:1 methyl erucate (
cis
-13)
24. C23:0 methyl tricosanoate
25. C24:0 methyl lignocerate
26. C20:5 methyl eicosapentaenoate
(
cis
-5,8,11,14,17)
27. C24:1 methyl nervonate (
cis
-15)
28. C22:6 methyl docosahexaenoate
(
cis
-4,7,10,13,16,19)
GC_FF00651
(CH
2
)
3
Si
C N
90%
O
C N
(CH
2
)
3
Si
C N
10%
O
Rt®-2330Structure
DoingDioxinAnalysis?
Rtx®-Dioxin2columnsprovidebetter resolution
andhighermaximum temperatures than
conventional columns. See
page96
.
Resolves
cis
and
trans
FAME isomers
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengthsmay have a slightly reduced
maximum temperature.
Rt®-2330Columns
(fusedsilica)
(highlypolar phase; 90%biscyanopropyl/10%phenylcyanopropyl polysiloxane—not bonded)
• General purpose columns for
cis
/
trans
FAMEs, dioxin isomers.
• Temperature range: 0 °C to275 °C.
• Equivalent toUSPG8 andG48phase.
Rt®-2330 isoneof themostpolar capillary column stationaryphases.Cyanogroupson
both sides of the polymer backbone give the phase a strong dipolemoment and high
selectivity for
cis
/
trans
compounds or compounds with conjugated double bonds.
Highly polar columns typically exhibit poor column efficiencies, highbleed, and short
column lifetimes when thermally cycled. To overcome some of these problems, we
developed a surface treatment that is more compatible with the Rt®-2330 phase. In
addition, our improved polymer produces columns with improved column efficiency
and lower bleed.
Because theRt®-2330 stationaryphase is not bonded, it shouldnot be solvent rinsed.
Rt®-2560Column
(fusedsilica)
(highlypolar phase; biscyanopropyl polysiloxane—not bonded)
• Application-specific column for
cis
/
trans
FAMEs.
• Stable to250 °C.
Because theRt®-2560 stationaryphase is not bonded, it shouldnot be solvent rinsed.
ID
df
temp. limits*
30-Meter
60-Meter
105-Meter
0.25mm 0.10µm 0 to 260/275°C
10708
10711
10714
0.20µm 0 to 260/275°C
10723
10726
10729
0.32mm 0.20µm 0 to 260/275°C
10724
10727
10730
0.53mm 0.10µm 0 to 260/275°C
10710
10713
0.20µm 0 to 260/275°C
10725
10728
ID
df
temp. limits
10-Meter
20-Meter
40-Meter
0.18mm 0.10µm 0 to 260/275°C 40701
40702
40703
ID
df
temp. limits
100-Meter
0.25mm 0.20µm 20 to 250°C 13199
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,104,105,106,107,108,109,110,111,112,113 115,116,117,118,119,120,121,122,123,124,...