Chromatography Columns 2013+ - page 108

51
GCCOLUMNS |
GENERALPURPOSECOLUMNS
Rtx®-20, Rtx®-35
similar
phase
SPB-20, AT-20, 007-7
CH
3
CH
3
Si
80%
O
Si
20%
O
Rtx
®
-20Structure
also
available
MetalMXT®Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page116
forourMXT®-20columns
and
page117
forourMXT®-35columns.
Rtx®-35AmineColumns
See
page65.
CH
3
CH
3
Si
65%
O
Si
35%
O
Rtx
®
-35Structure
similar
phases
DB-35, HP-35, SPB-35, SPB-608
Rtx®-20Columns
(fusedsilica)
(low tomidpolarityphase; Crossbond®20%diphenyl/80%dimethyl polysiloxane)
• General purpose columns for volatile compounds, flavor compounds,
alcoholic beverages.
• Temperature range: -20 °C to320 °C.
• Equivalent toUSPG28,G32phases.
Rtx®-20 polymer is synthesized to exacting standards. All residual catalysts and low
molecular weight fragments are removed from the polymer, providing a tight mono-
modal distribution and extremely lowbleed.
Rtx®-35Columns
(fusedsilica)
(midpolarityphase; Crossbond®35%diphenyl/65%dimethyl polysiloxane)
• General purpose columns for organochlorine pesticides, PCB congeners (e.g.
Aroclormixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
• Temperature range: 40 °C to320 °C.
• Equivalent toUSPG42phase.
AnRtx®-35 column is apopular confirmation column for pesticides andherbicides, in
conjunctionwith an Rtx®-5 or Rtx®-1701 column. The higher phenyl content causes
useful elutionorder and retention time changes.
ID
df
temp. limits
15-Meter
30-Meter
0.25mm 0.25µm -20 to 300/320°C
10320
10323
0.50µm -20 to 290/310°C
10335
10338
1.00µm -20 to 280/300°C
10350
10353
0.32mm 0.25µm -20 to 300/320°C
10321
10324
0.50µm -20 to 290/310°C
10336
10339
1.00µm -20 to 280/300°C
10351
10354
0.53mm 0.25µm -20 to 260/280°C
10322
10325
1.00µm -20 to 260/280°C
10352
10355
ID
df
temp. limits
15-Meter
30-Meter
0.25mm 0.25µm
40 to 320°C
10420
10423
0.50µm
40 to 310°C
10435
10438
1.00µm
40 to 290°C
10450
10453
0.32mm 0.25µm
40 to 320°C
10421
10424
0.50µm
40 to 310°C
10436
10439
1.00µm
40 to 290°C
10451
10454
0.53mm 0.25µm 40 to 260/280°C
10422
10425
0.50µm
40 to 300°C
10437
10440
1.00µm
40 to 290°C
10452
10455
1.50µm
40 to 280°C
10467
10470
3.00µm 40 to 240/260°C
10482
10485
ID
df
temp. limits
10-Meter
20-Meter
0.18mm 0.20µm 40 to 300/320°C
40401
40402
0.40µm 40 to 290/310°C
40410
40411
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,98,99,100,101,102,103,104,105,106,107 109,110,111,112,113,114,115,116,117,118,...