Chromatography Columns 2013+ - page 113

56
GCCOLUMNS |
GENERALPURPOSECOLUMNS
Rtx®-1701, Rtx®-225
CH
3
(CH
2
)
3
CH
3
Si
86%
O
Si
C N
14%
O
Rtx
®
-1701Structure
similar
phases
DB-1701, HP-1701, SPB-1701,VF-1701,
CP-Sil 19CB
also
available
MetalMXT®Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page118
forourMXT®-1701
columns.
Get theprotectionwithout theconnection!
For Rtx®-1701columnswithbuilt-in
Integra-Guard®guardcolumns,
see
page35
.
Integra-Guard®built-inguardcolumn
similar
phases
DB-225, HP-225, SPB-225, CP-Sil 43CB
CH
3
(CH
2
)
3
CH
3
Si
50%
O
Si
C N
50%
O
Rtx
®
-225Structure
Rtx®-225Columns
(fusedsilica)
(polar phase; Crossbond®50% cyanopropylmethyl/50%phenylmethyl polysiloxane)
• General purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.
• Temperature range: 40 °C to240 °C.
• Equivalent toUSPG7,G19phases.
The cyanopropyl-containingRtx®-225phase is slightly lesspolar thanbondedpolyeth-
ylene glycol (PEG) phases, but it canbeused formanyof the same applications.
Improvements to theRtx®-225polymerhave increased thermal stability, reducedbleed,
and improved inertness.TheRtx®-225columnprovidesa20°C thermal stabilityadvan-
tageoverother“225”columnsbecauseof ouruniquepolymer synthesis technologyand
proprietary siloxane deactivation. Inmost similar columns, the Carbowax® deactiva-
tion layer is not fully compatible with the cyanopropyl siloxane polymer, which can
cause adsorption, tailingof active compounds, and lower efficiency.
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengthsmay have a slightly reduced
maximum temperature.
Rtx®-1701Columns
(fusedsilica)
(midpolarityphase; Crossbond®14% cyanopropylphenyl/86%dimethyl polysiloxane)
• General purpose columns for alcohols, oxygenates, PCB congeners (e.g.Aroclor
mixes), pesticides.
• Temperature range: -20 °C to280 °C.
• Equivalent toUSPG46phase.
Rtx®-1701 is one of themore popular stationaryphases used in capillaryGC. Themix
of cyano andphenyl functional groups increases the polarity andoffers adifferent elu-
tion order relative to less polar Rtx®-1 or Rtx®-5 columns. An Rtx®-1701 column is
ideal for confirmationanalysis, incombinationwithanRtx®-35orRtx®-5column.The
polymer is fully characterized to ensure long-term reproducibility, column-to-column
consistency, and lowbleed, evenwith sensitive detectors such as ECDs andMSDs.
ID
df
temp. limits*
15-Meter
30-Meter
60-Meter
0.25mm 0.10µm -20 to 280°C
12011
0.25µm -20 to 280°C 12020
12023
12026
0.50µm -20 to 270/280°C 12035
12038
12041
1.00µm -20 to 260/280°C 12050
12053
12056
0.32mm 0.10µm -20 to 280°C
12009
0.25µm -20 to 280°C 12021
12024
12027
0.50µm -20 to 270/280°C 12036
12039
12042
1.00µm -20 to 260/280°C 12051
12054
12057
1.50µm -20 to 240/260°C 12066
12069
12072
0.53mm 0.10µm -20 to 270/280°C 12007
0.25µm -20 to 270/280°C 12022
12025
12028
0.50µm -20 to 260/270°C 12037
12040
12043
1.00µm -20 to 250/270°C 12052
12055
12058
1.50µm -20 to 240/260°C 12067
12070
12073
3.00µm -20 to 230/250°C 12082
12085
12088
ID
df
temp. limits
10-Meter
20-Meter
0.10mm 0.10µm -20 to 280°C 42201
42202
0.18mm 0.20µm -20 to 280°C 42001
42002
0.40µm -20 to 270/280°C 42010
42011
ID
df
temp. limits*
15-Meter
30-Meter
60-Meter
0.25mm 0.10µm 40 to 220/240°C 14005
14008
0.25µm 40 to 220/240°C 14020
14023
14026
0.50µm 40 to 220/240°C 14035
14038
14041
0.32mm 0.10µm 40 to 220/240°C 14006
14009
0.25µm 40 to 220/240°C 14021
14024
14027
0.50µm 40 to 220/240°C 14036
14039
14042
1.00µm 40 to 200/220°C 14051
14054
14057
0.53mm 0.10µm 40 to 200/220°C 14007
14010
0.25µm 40 to 200/220°C 14022
14025
0.50µm 40 to 200/220°C 14037
14040
14043
1.00µm 40 to 200/220°C 14052
14055
14058
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011