Chromatography Columns 2013+ - page 111

54
GCCOLUMNS |
GENERALPURPOSECOLUMNS
Rtx®-200, Rtx®-200MS
CH
3
CF
3
C
2
H
4
Si
O
Rtx
®
-200Structure
also
available
MetalMXT®Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page118
forourMXT®-200
columns.
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengthsmay have a slightly reduced
maximum temperature.
similar
phases
DB-200,DB-210,VF-200ms
Rtx®-200Columns
(fusedsilica)
(midpolarityphase; Crossbond® trifluoropropylmethyl polysiloxane)
Rtx®-200/Rtx®-200MS (fusedsilica)
• General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones,
silanes, glycols. Excellent confirmation column,with anRtx®-5 column,
for phenols, nitrosamines, organochlorine pesticides, chlorinatedhydrocarbons,
and chlorophenoxyherbicides.
• Temperature range: -20 °C to340 °C.
• Equivalent toUSPG6phase.
Rtx®-200 columns have accomplishedmany difficult separations not possible on any
other bonded stationary phase.Many analysts consider these the best,most inertmid-
polarity columns available.The trifluoropropyl stationaryphasehas aunique selectivi-
ty that changes elution orders and resolves compounds that phenyl, cyano, or
Carbowax® phases cannot. The Rtx®-200 column offers exceptional thermal stability,
low bleed, and superior inertness—even for active compounds such as phenols, and
with sensitive detectors such as ECDs,NPDs, andMSDs.
Rtx®-200MS—Low-bleedGC/MSColumns
(fusedsilica)
(midpolarityphase; Crossbond® trifluoropropylmethyl polysiloxane)
Column specifically tested for lowbleedperformance.
ID
df
temp. limits*
15-Meter
30-Meter
60-Meter
105-Meter
0.25mm 0.25µm -20 to 320/340°C 15020
15023
15026
15029
0.50µm -20 to 310/330°C 15035
15038
15041
15044
1.00µm -20 to 290/310°C 15050
15053
15056
15059
0.32mm 0.25µm -20 to 320/340°C 15021
15024
15027
15030
0.50µm -20 to 310/330°C 15036
15039
15042
15045
1.00µm -20 to 290/310°C 15051
15054
15057
15060
1.50µm -20 to 280/300°C 15066
15069
15072
15075
0.53mm 0.25µm -20 to 310/330°C 15022
15025
15028
0.50µm -20 to 300/320°C 15037
15040
15043
1.00µm -20 to 290/310°C 15052
15055
15058
1.50µm -20 to 280/300°C 15067
15070
15073
3.00µm -20 to 260/280°C 15082
15085
15088
15091
ID
df
temp. limits
10-Meter
20-Meter
40-Meter
0.18mm 0.20µm -20 to 310/330°C 45001
45002
45003
0.40µm -20 to 310/330°C 45010
45011
45012
ID
df
temp. limits
30-Meter
0.25mm 0.10µm -20 to 320/340°C
15608
0.25µm -20 to 320/340°C
15623
0.50µm -20 to 310/330°C
15638
1.00µm -20 to 290/310°C
15653
0.32mm 0.10µm -20 to 320/340°C
15609
0.25µm -20 to 320/340°C
15624
0.50µm -20 to 310/330°C
15639
1.00µm -20 to 290/310°C
15654
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,101,102,103,104,105,106,107,108,109,110 112,113,114,115,116,117,118,119,120,121,...