GENERALPURPOSECOLUMNS
Rtx®-1301, Rtx®-624
CH
3
(CH
2
)
3
CH
3
Si
94%
O
Si
C N
6%
O
Rtx
®
-1301Structure
similar
phases
DB-1301,DB-624, HP-1301, HP-624, SPB-1301,
SPB-624,VF-1301,VF-624ms, CP-1301,
CP-Select 624CB
Get theprotectionwithout theconnection!
For Rtx®-1301andRtx®-624columnswith
built-in Integra-Guard®guardcolumns,
see
page35
.
Integra-Guard®built-inguardcolumn
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengthsmay have a slightly reduced
maximum temperature.
Rtx®-1301 (G43)Columns
(fusedsilica)
(low tomidpolarityphase; Crossbond®6% cyanopropylphenyl/94%dimethyl polysiloxane)
• General purpose columns for residual solvents, alcohols, oxygenates, and volatile
organic compounds.
• Temperature range: -20 °C to280 °C.
• Equivalent toUSPG43phase.
Manyanalysts feel theRtx®-1301 columnhas thebest cyanosiloxanebonded stationary
phase available,withnoother columnmanufacturerproviding lower bleed, longer life-
time, or better inertness.Our polymer is fully characterized to ensure long-term repro-
ducibility,column-to-columnconsistency,and lowbleed—evenwith sensitivedetectors
such as ECDs andMSDs.
similar
phases
DB-1301,DB-624, HP-1301, HP-624, SPB-1301,
SPB-624,VF-1301,VF-624ms, CP-1301,
CP-Select 624CB
Rtx®-624Columns
(fusedsilica)
(low tomidpolarityphase; Crossbond®6% cyanopropylphenyl/94%dimethyl polysiloxane)
• Application-specific columns for volatile organic pollutants.Recommended inUS
EPAmethods for volatile organic pollutants.
• Temperature range: -20 °C to240 °C.
• Equivalent toUSPG43phase.
Theuniquepolarityof theRtx®-624columnmakes it ideal foranalyzingvolatileorgan-
ic pollutants.Although theRtx®-502.2 column is recommended inmanymethods, the
Rtx®-624 column offers better resolution of early eluting compounds. The Rtx®-624
phase produces greater than 90% resolutionof the first six gases inEPAMethods 8260
and524.2.This stationaryphase is especiallywell-suited forEPAMethod524.2 revision
IV since it resolves 2-nitropropane from 1,1-dichloropropanone,which share quantifi-
cation ionm/z 43 andmust be separated chromatographically.
also
available
MetalMXT®Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page117
forourMXT®-1301
columnsand
page121
forourMXT®-624
columns.
Rtx®-624Structure
please
note
Rtx®-1301columnsandRtx®-624columnsareexactly the samecolumns.
CH
3
(CH
2
)
3
CH
3
Si
94%
O
Si
C N
6%
O
ID
df
temp. limits* 15-Meter
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 0.25µm -20 to 280°C 16020
16023
$450
16026
0.50µm -20 to 270°C 16035
16038
$450
16041
1.00µm -20 to 260°C 16050
16053
$450
16056
1.40µm -20 to 240°C
16016
0.32mm 0.25µm -20 to 280°C 16021
16024
$480
16027
0.50µm -20 to 270°C 16036
16039
$480
16042
1.00µm -20 to 260°C 16051
16054
$480
16057
1.50µm -20 to 250°C 16066
16069
$480
16072
1.80µm -20 to 240°C
16092
$480
16093
0.53mm 0.25µm -20 to 280°C 16022
16025
$540
16028
0.50µm -20 to 270°C 16037
16040
$540
16043
1.00µm -20 to 260°C 16052
16055
$540
16058
1.50µm -20 to 250°C 16067
16070
$540
16073
3.00µm -20 to 240°C 16082
16085
$540
16088
16076
16091
ID
df
temp. limits
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 1.40µm -20 to 240°C 10968
10969
0.32mm 1.80µm -20 to 240°C 10970
10972
0.45mm 2.55µm -20 to 240°C
10982
0.53mm 3.00µm -20 to 240°C 10971
10973
10974
10975
ID
df
temp. limits
20-Meter
40-Meter
0.18mm 1.00µm -20 to 240°C
40924
40925
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,102,103,104,105,106,107,108,109,110,111 113,114,115,116,117,118,119,120,121,122,...
Powered by FlippingBook