Table of Contents Table of Contents
Previous Page  92 / 628 Next Page
Information
Show Menu
Previous Page 92 / 628 Next Page
Page Background

90

www.restek.com

GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Petroleum & Petrochemical

Petroleum Oxygenates on Rt®-TCEP

Aromatics & Oxygenates in Gasoline Analysis

Save money!

Get six columns for the price of five.

Call 800-356-1688, ext. 3

, or your

Restek representative for details!

GC_PC00195

Column

Rt®-TCEP, 60 m, 0.25 mm ID, 0.40 µm (cat.# 10999)

Sample

Conc.:

500 ppm

Injection

Inj. Vol.:

1.0 µL split

Inj. Temp.:

200 °C

Split Vent

Flow Rate:

46 mL/min

Oven

Oven Temp.:

60 °C (hold 5 min) to 100 °C at 5 °C/min (hold 10 min)

Carrier Gas

He, constant pressure

Linear Velocity:

30 cm/sec @ 80 °C

Detector

FID@ 200 °C

Notes

FID sensitivity: 6.4 x 10

-11

AFS

Peaks

1. Methyl

tert

-butyl ether

2.

n

-Undecane

3.

tert

-Butanol

4. Methanol

5. Isopropyl alcohol

6. Ethanol

7.

n

-Dodecane

8.

n

-Tridecane

9.

n

-Butanol

free literature

Analyzing Oxygenates in

Gasoline Using TCEP and

Rtx®-1/MXT®-1 Columns

Download your

free copy from

lit. cat.# 59587A

www.restek.com

Rt®-TCEP Columns

(fused silica)

(highly polar phase; 1,2,3-tris[2-cyanoethoxy]propane—not bonded)

• General-purpose columns, ideal for aromatics and oxygenates in gasoline.

• Temperature range: 0 °C to 135 °C.

Most gasolines contain aliphatic hydrocarbons up to

n

-dodecane (C12). To improve

identification of the aromatics and oxygenates, it is desirable to elute benzene after

C11 and toluene after C12. The extremely polar Rt®-TCEP stationary phase provides a

retention index for benzene greater than 1,100 and permits the separation of alcohols

and aromatics from the aliphatic constituents in gasoline.

Rt®-TCEP columns have the same high polarity as TCEP packed columns (precolumns

in ASTMMethod D4815 for the analysis of petroleum oxygenates), with the efficiency

of a capillary column. The result is a column that can separate a wide variety of com-

pounds with an elution pattern unattainable using other high polarity siloxanes.

The Rt®-TCEP column incorporates a nonbonded stationary phase coated on a surface

specialized for enhanced polymer stability and extended column lifetime. Solvent rins-

ing should be avoided. Conditioning is necessary only if the column is to be used at

temperatures near the maximum operating temperature.

similar phases

SPB-TCEP, CP-TCEP

30-Meter

60-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

0.25 mm 0.40 µm 0 to 135 °C

10998

10999