Table of Contents Table of Contents
Previous Page  87 / 628 Next Page
Information
Show Menu
Previous Page 87 / 628 Next Page
Page Background www.restek.com

85

GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Foods, Flavors, & Fragrances

Pesticide Analysis in Cannabis

Rxi®-5Sil MS Columns

(fused silica)

(low-polarity phase; Crossbond® 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane)

• Engineered to be a low-bleed GC-MS column.

• Excellent inertness for active compounds.

• General-purpose columns—ideal for GC-MS analysis of semivolatiles, polycyclic

aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines,

organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities,

and hydrocarbons.

• Temperature range: -60 °C to 350 °C.

Rxi®-5Sil MS Structure

95%

5%

CH

3

CH

3

Si

O

O

CH

3

CH

3

Si

CH

3

CH

3

Si

similar phases

DB-5ms, DB-5msUI, VF-5ms, ZB-5ms,

ZB-SemiVolatiles, Rtx-5Sil MS

30-Meter

ID

df

temp. limits

cat.#

price

0.25 mm 0.25 µm -60 to 320/350 °C

13623

0.50 µm -60 to 320/350 °C

13638

Rxi®-5Sil MS with Integra-Guard®

• Extend column lifetime.

• Eliminate leaks with a built-in retention gap.

• Inertness verified by isothermal testing.

Description

qty.

cat.#

price

30 m, 0.25 mm ID, 0.25 µm Rxi-5Sil MS w/5 m Integra-Guard Column

ea.

13623-124

30 m, 0.25 mm ID, 0.50 µm Rxi-5Sil MS w/5 m Integra-Guard Column

ea.

13638-124

Marijuana Pesticides by GCxGC on Rxi®-5Sil MS and Rtx®-200

GC_FF1205

Column

: Rxi®-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623); Rtx®-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15020);

Sample:

Diluent: Toluene;

Injection:

Inj. Vol.: 1 µL splitless (hold 1 min); Liner: Sky®

4 mm single taper w/wool (cat.# 23303.1); Inj. Temp.: 250 °C; Purge Flow: 40 mL/min;

Oven:

Oven Temp.: Rxi®-5Sil MS: 80 °C (hold 1 min) to 310 °C at 5 °C/min; Rtx®-200: 85 °C (hold 1 min) to 315 °C

at 5 °C/min;

Carrier Gas:

He, corrected constant flow (2 mL/min);

Modulation:

Modulator Temp. Offset: 20 °C; Second Dimension Separation Time: 3 sec; Hot Pulse Time: 0.9 sec; Cool Time between

Stages: 0.6 sec;

Detector:

TOFMS; Transfer Line Temp.: 290 °C; Analyzer Type: TOF; Source Temp.: 225 °C; Electron Energy: 70 eV; Mass Defect: -20 mu/100 u; Solvent Delay Time: 5 min; Tune Type:

PFTBA; Ionization Mode: EI; Acquisition Range: 45-550 amu; Spectral Acquisition Rate: 100 spectra/sec;

Instrument:

LECO Pegasus 4D GCxGC-TOFMS;

Notes:

Rtx®-200 (cat.# 15020) is a 15 m column.

A 1.3 m section was used as the second dimension column.

For a peak list, visit

www.restek.com

and enter chromatogram GC_FF1205 in the search function.

Similar to: (5%-phenyl)-methylpolysiloxane

Growing Analytical

Solutions for Medical

Cannabis Labs

www.restek.com/ c

annabis