Table of Contents Table of Contents
Previous Page  97 / 628 Next Page
Information
Show Menu
Previous Page 97 / 628 Next Page
Page Background www.restek.com

95

GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Pharmaceutical

Organic Volatile Impurities (OVI) Analysis

G16 phase

ordering note

Get the protection without the connection!

For Stabilwax® columns with built-in

Integra-Guard® guard columns, see

page 23

.

Residual Solvents (Class 1) on Stabilwax® (G16)

GC_PH00951

Column

Stabilwax®, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)

Sample

Residual solvents - class 1 (cat.# 36279)

in 20 mL headspace vial (cat.# 24685)

Diluent:

Water

Injection

Inj. Vol.:

1.0 µL headspace-syringe split (split ratio 5:1)

Liner:

2 mm splitless (cat.# 20712)

Inj. Temp.:

140 °C

Headspace-Syringe

Instrument:

Overbrook Scientific HT200H

Syringe Temp.:

100 °C

Sample Temp.:

80 °C

Sample Equil. Time: 45 min

Inj. Speed:

8

Inj. Dwell:

5 sec

Oven

Oven Temp.:

50 °C (hold 20 min) to 165 °C at 6 °C/min (hold 20 min)

Carrier Gas

He, constant flow

Flow Rate:

2.15 mL/min

Linear Velocity:

35.2 cm/sec

Detector

FID@ 250 °C

Peaks

1. 1,1-Dichloroethene

2. 1,1,1-Trichloroethane

3. Carbon tetrachloride

4. Benzene

5. 1,2-Dichloroethane

System suitability

criteria met

free literature

Custom Residual Solvent

Mixes

Download your

free copy from

lit. cat.#

PHTS1212

www.restek.com

Stabilwax® Columns

(fused silica)

(polar phase; Crossbond® polyethylene glycol)

• Most stable polyethylene glycol (PEG) column available.

• Rugged enough to withstand repeated water injections.

• Lowest-bleed PEG column on the market; long column lifetimes.

• Temperature range: 40 °C to 260 °C.

• Equivalent to USP G14, G15, G16, G20, and G39 phases.

Restek’s polar-deactivated surface tightly binds the Carbowax® polymer and increases

thermal stability, relative to competitive columns. Because of the increased stability

produced by the bonding process, Stabilwax® columns exhibit long column lifetimes,

even when programming repeatedly up to 260 °C. The bonding mechanism of the

column also produces polar compound retention times that do not shift, as is often

observed on other wax-type columns. In addition, this bonding mechanism produces

a column that can be rejuvenated by solvent washing.

Stabilwax® Structure

H

H

C C O

H

H

similar phases

HP-INNOWax, CP-Wax 52 CB, VF-WAX MS,

ZB-WAXplus

15-Meter

30-Meter

60-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.10 µm 40 to 250/260 °C 10605

10608

10611

0.25 µm 40 to 250/260 °C 10620

10623

10626

0.50 µm 40 to 250/260 °C 10635

10638

10641

0.32 mm 0.25 µm 40 to 250/260 °C 10621

10624

10627

0.50 µm 40 to 250/260 °C 10636

10639

10642

1.00 µm 40 to 240/250 °C 10651

10654

10657

0.53 mm 0.25 µm 40 to 250/260 °C 10622

10625

10628

0.50 µm 40 to 250/260 °C 10637

10640

10643

1.00 µm 40 to 240/250 °C 10652

10655

10658

1.50 µm 40 to 230/240 °C 10666

10669

10672

2.00 µm 40 to 220/230 °C 10667

10670

10-Meter

20-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

0.15 mm 0.15 µm 40 to 250/260 °C 43830

43831

0.18 mm 0.18 µm 40 to 250 °C

40602