Table of Contents Table of Contents
Previous Page  100 / 628 Next Page
Information
Show Menu
Previous Page 100 / 628 Next Page
Page Background

98

www.restek.com

GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Specially Deactivated

Acidic Compounds Analysis

crossbond® technology

Reduces bleed, prolongs column lifetime, and

allows rejuvenation through solvent rinsing.

Underivatized Alcoholic Beverage Acids and Methyl Esters on Stabilwax®-DA

1

2

3

4 5

6

7

8

9

10

11

12

13

14

15

16

17

3

4

5

6

7

8

9

Time (min)

11

10

12

13

14

15

GC_FF00500

Column

Stabilwax®-DA, 30 m, 0.18 mm ID, 0.18 µm (cat.# 550752)

Sample

Diluent:

Ethyl acetate

Injection

Inj. Vol.:

1 µL splitless (hold 0.5 min)

Liner:

Splitless (4 mm ID) w/glass wool (cat.# 20814-202.1)

Inj. Temp.:

240 °C

Oven

Oven Temp.:

70 °C to 240 °C at 12 °C/min (hold 3 min)

Carrier Gas

H

2

, constant linear velocity

Linear Velocity:

28 psi, 193.1 kPa @ 240 °C

Detector

FID

Make-up Gas

Type:

N

2

Peaks

Conc.

(µg/mL)

1. Ethyl octanoate

100

2. Acetic acid

100

3. Propionic acid

100

4. Isobutyric acid

100

5. 3-Decanol

50

6. Ethyl decanoate

50

7. Ethyl laurate

50

8.

cis

-Lactone

100

9. 2-Phenylethanol

50

10.

trans

-Lactone

100

11. Methyl myristate

50

12. Ethyl myristate

50

13. Octanoic acid

100

14. Ethyl palmitate

50

15. Decanoic acid

100

16. Dodecanoic acid

100

17. Vanillin

100

please note

Stabilwax®-DA columns should not be rinsed

with water.

Stabilwax®-DA Columns

(fused silica)

(polar phase; Crossbond® acid-deactivated Carbowax® polyethylene glycol—for acidic compounds)

• Application-specific columns for free (underivatized) acids, some inorganic acids.

• Resistant to oxidative damage.

• Temperature range: 40 °C to 260 °C.

• Equivalent to USP G25, G35 phases.

Stabilwax®-DA bonded polyethylene glycol has an acidic functionality incorporated

into the polymer structure. This permits analysis of acidic compounds without de-

rivatization, significantly reduces adsorption of acids, and increases sample capacity

for volatile free acids. Stabilwax®-DA columns last longer and give better peak shapes

for high molecular weight acids.

Some inorganic acids also chromatograph well on a Stabilwax®-DA column; the limita-

tion is the volatility of the acidic compound.

similar phases

HP-FFAP, DB-FFAP, CP-WAX 58 FFAP CB,

NUKOL, ZB-FFAP

15-Meter

30-Meter

60-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.10 µm 40 to 250/260 °C 11005

11008

0.25 µm 40 to 250/260 °C 11020

11023

11026

0.50 µm 40 to 250/260 °C 11035

11038

11041

0.32 mm 0.10 µm 40 to 250/260 °C

11009

0.25 µm 40 to 250/260 °C 11021

11024

11027

0.50 µm 40 to 250/260 °C 11036

11039

11042

1.00 µm 40 to 240/250 °C 11051

11054

11057

0.53 mm 0.10 µm 40 to 250/260 °C 11007

0.25 µm 40 to 250/260 °C 11022

11025

0.50 µm 40 to 250/260 °C 11037

11040

1.00 µm 40 to 240/250 °C 11052

11055

11058

1.50 µm 40 to 230/240 °C 11062

11065

11068