Restek 2011/12 Chromatography Catalog - page 719

719
HPLC CHROMATOGRAMS |
FOODS & FLAVORS
Food Contaminants
Carbamate Pesticides on Ultra II® Carbamate (LC/MS/MS)
Time (min.)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Peaks
RT (min.)
Transition 1
Transition 2
1. Aldicarb sulfone
1.9
223.1
86.1 223.1
148.0
2. Aldicarb sulfoxide
2.2
207.1
132.1 207.1
89.1
3. Oxamyl
2.4
237.1
72.1 237.1
90.1
4. Methomyl
2.6
163.1
88.1 163.1
106.0
5. 3-Hydroxycarbofuran
3.5
238.1
163.1 238.1
181.2
6. Aldicarb
4.5
208.1
116.0 208.1
88.9
7. Propoxur
5.1
210.1
111.0 210.1
168.1
8. Carbofuran
5.3
222.1
165.2 222.1
123.0
9. Carbaryl
5.8
202.1
145.1 202.1
127.1
10. Methiocarb
7.0
226.1
169.2 226.1
121.0
1
2
3
4
5
6
7
8
9
10
LC_EV0510
Column
Ultra II
®
Carbamate (cat.# 9611312)
Dimensions:
100 mm x 2.1 mm ID
Particle Size:
3 µm
Pore Size:
100 Å
Temp.:
35 °C
Sample
531.1 Carbamate Pesticide Calibration Mixture
(cat.# 32273)
Diluent:
acetonitrile
Conc.:
100 ppb each pesticide
Inj. Vol.:
5 µL
Mobile Phase
A:
10 mM NH
4
OAc in water
B:
10 mM NH
4
OAc in methanol
Time (min.)
%B
0
10
1
10
8
90
10
90
11
10
Flow:
0.5 mL/min.
Instrument
Applied Biosystems/MDS Sciex LC/MS/MS System
Detector
Applied Biosystems/MDS Sciex LC/MS/MS
Model #:
4000 QTRAP™ LC/MS/MS system
Ion Source:
TurboIonSpray
®
Ion Mode:
ESI+
Ion Spray Voltage: 5 kV
Gas 1:
40 psi (275.8 kPa)
Gas 2:
60 psi (413.7 kPa)
Source Temp.:
500 °C
NEW!
Carbamates in Orange Oil on Ultra Carbamate (LC-TOFMS)
Peak List:
1. aldicarb sulfone
2. aldicarb sulfoxide
3. oxamyl
4. methomyl
5. 3-hydroxycarbofuran
6. aldicarb
7. propoxur
8. carbofuran
9. carbaryl
10. methiocarb
11. BDMC (IS)
Sample:
531.1 Carbamate Pesticide Calibration Mix (cat.# 32273) and
Internal Standard 4-bromo-3,5-dimethylphenyl-N-methylcarbamate
(cat.# 32274) 50:50 spiked into unprocessed orange oil at 10ppm
Inj.:
3µL
Conc.:
10ppm
Sample diluent:
methanol
Matrix:
orange oil
Column:
Ultra Carbamate
Cat. #:
9177352
Dimensions:
50mm x 2.1mm
Particle size:
3µm
Pore size:
100Å
Conditions:
Mobile phase:
A: 2mM ammonium acetate:methanol, 90:10
B: 2mM ammonium acetate:methanol, 10:90
Time (min.)
%B
0
20
20
100
25
100
Flow:
200µL/min.
Temp.:
ambient
Det.:
LECO Unique
®
LC-TOFMS
Interface:
ESI
Ion mode:
Positive
Temp.:
130°C
Nebulizer pressure:
100kPa
Desolvation gas (N2): 4,000cc/min.
Interface temperature: 120°C
Nozzle:
(+) 62V
Capillary:
(+) 2.75kV
LC_FF0472
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,709,710,711,712,713,714,715,716,717,718 720,721,722,723,724,725,726,727,728,729,...791