Direct Injection Liners for PerkinElmer GCs
(For 0.32/0.53mm IDColumns)
Benefits/Uses
ID*/OD&
Length (mm)
Similar to
PE part#
ea.
cat.#
5-pk.
25-pk.
Auto SYSDrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.2OD x 92.1
—
20819
20822
—
Auto SYSDrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.2OD x 92.1
—
21293
21294
—
Auto SYSGooseneck DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
5.0OD x 92.1
—
21295
21296
—
Auto SYSGooseneck DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.2OD x 92.1
—
21297
21298
—
Direct Injection Liners for Thermo Finnigan 8000
& TRACE
™
Series GCs (0.32& 0.53mm ID columns)
Benefits/Uses
ID*/OD&
Length (mm)
Similar to
TF part#
ea.
cat.#
5-pk.
25-pk.
DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery, & linearity
5.0 ID
8.0OD x 105
—
22411
22412
—
DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery, & linearity
5.0 ID
8.0OD x 105
—
22413
22414
—
Direct Injection Liners for Agilent 5890& 6890GCs
(For 0.25/0.32/0.53mm IDColumns)
Benefits/Uses
ID*/OD&
Length (mm)
Similar to
Agilent part#
ea.
cat.#
5-pk.
25-pk.
DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
—
21054
21055
20998
Siltek™DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
—
21054-214.1
21055-214.5 20998-214.25
DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
G1544-80730
20756
20771
—
DoubleGooseneck DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
—
20508
20509
—
DoubleGooseneck DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
G1544-80700
20954
20989
—
Siltek™1mmDrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
1.0 ID
6.3OD x 78.5
—
21390-214.1
21391-214.5
—
At-a-Glance
Product
Information
fromRestek
Drilled Uniliner
®
GC Inlet Liners
Holemakes direct injection possible
with EPC-equipped Agilent 6890 GCs!
010 %
deactivated
all liners are
Direct Injection Liners for ShimadzuGCs
(For 0.32/0.53mm IDColumns)
Benefits/Uses
ID*/OD&
Length (mm)
Similar to
Shimadzu part#
ea.
cat.#
5-pk.
25-pk.
Open-topDrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
3.5 ID
5.0OD x 95
—
21285
21286
—
Open-topDrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
3.5 ID
5.0OD x 95
—
21287
21288
—
Gooseneck DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
3.5 ID
5.0OD x 95
—
21289
21290
—
Gooseneck DrilledUniliner®(hole on bottom)
trace, active samples, high
recovery & linearity
3.5 ID
5.0OD x 95
—
21291
21292
—
All liners are shipped intermediate
polarity (IP) deactivated unless
otherwise requested.
*Nominal ID at syringe needle expulsion point.
Direct Injection Liners for Varian 1177GCs
(For 0.25/0.32/0.53mm IDColumns)
Benefits/Uses
ID*/OD&
Length (mm)
Similar to
Varian part#
cat.#
ea.
cat.#
5-pk.
cat.#
25-pk.
DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
—
21470
21471
—
DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
—
21468
21469
—