fastfacts07 - page 133

Allure
C18
HPLCColumns
MaximumRetention andPeak Symmetry
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
At-a-Glance
Product
Information
fromRestek
Feature
Highly base-deactivated silica.
Unique bonding technology
resists hydrolysis of bonded
phase.
Excellent batch-to-batch
consistency.
High carbon load phase.
Benefit
Excellent peak symmetry for basic
compounds.
More consistent retention times
and longer column lifetime.
Reproducible analyses.
Improved LC/MS sensitivity
andHPLC resolution.
Features & Benefits
Allure
C18 high carbon
load phase is ideal for
LC/MS applications
800-356-1688
814-353-1300
The sensitivity of LC/MS analyses
is strongly affected by the percentage of
organic content in the mobile phase.
High organic content can greatly
increase LC/MS signal-to-noise ratio.
However, most commercial C18 phases
containonly10 to15%carbon loadso that
lessorganicmustbeusedinthemobilephase
to retain solutes. TheAllure
C18 phase
has a 27% carbon load, which results in
increased retention and increasedLC/MS
sensitivity, evenwithhighorganicmobile
phases. In theLC/MSanalysisof steroids,
theAllure
C18 column shows a26% in-
crease in sensitivity when compared to a
conventionalC18phase (Figure2).
Figure1
Allure
C18separatesallUSEPAMethod8330explosives inunder 10minutes.
Restek’sAllure
C18 column is designed using a simple yet unique bonding
chemistry that offers improved resistance to hydrolysis and superior batch-
to-batch reproducibility. The high carbon load phase exhibits maximum
retention characteristics, making it ideal for liquid chromatography/mass
spectrometry (LC/MS) applications. The phase is bonded onto a highly
base-deactivatedType B silica, resulting in improved peak symmetry, even
for basic analytes. TheAllure
C18 column can be used to analyze awide
range of compounds, from steroids and antibiotics to explosives (Figure 1).
Peak List:
1. HMX
2. RDX
3. 1,3,5-trinitrobenzene
4. 1,3-dinitrobenzene
5. tetryl
6. nitrobenzene
7. 4-amino-2,6-dinitrotoluene
8. 2-amino-4,6-dinitrotoluene
9. trinitrotoluene
10. 2,6-dinitrotoluene
11. 2,4-dinitrotoluene
12. 2-nitrotoluene
13. 4-nitrotoluene
14. 3-nitrotoluene
Sample:
Inj.:
5µL
Conc.: 50µg/mL
Solvent: water:methanol (1:1)
0
2
4
6
8
10 min.
1
2
5
6
7
8
9
10
11
12
13
14
4
3
Column:
Allure
C18
Dimensions: 150 x 4.0mm
ParticleSize: 5µm
Pore Size:
60Å
Conditions:
MobilePhase: water:methanol
(45:55, v/v)
Flow:
1.0mL/min.
Temp.:
45°C
Det.:
UV@ 254nm
LC_0065
Figure2
Allure
TM
C18ColumnsShowa
26% Increase inLC/MSSensitivity for
SlightlyPolarSteroidsCompared to
ConventionalC18
1
2
3
0
1
2
3
4min.
Column:
Catalog#:
9164552
Dimensions:
50x2.1mm
Particlesize:
5µm
Poresize:
60Å
Conditions:
Scanrange:
320-520amu
Flowrate:
0.4mL/min.
LC/MSInterface: Positive ion
ESI-TOF
Voltage:
3800V
Nozzletemp.:
160V
Nozzlevolt.:
190V
PeakList
1. deoxycorticosterone
glucoside
2. deoxycorticosterone
3. deoxycorticosterone
acetate
LC_0111
Data Courtesy of Shane Needham, Pfizer Inc
Allure
C18
H
2
O:MeOH(33:67)
4191.1cps
ConventionalC18
H
2
O:MeOH(40:60)
3324.0cps