Table of Contents Table of Contents
Previous Page  139 / 413 Next Page
Information
Show Menu
Previous Page 139 / 413 Next Page
Page Background

Figure 1

Chlo rinated pesticide residu es

in

olive oil are easily separated

on either Rtx®-CLPesticid es 2 or Rxi®-SSil MS columns.

A. Rtx®-CLPesticides2

11 12 131415

18 19

20

4

9

10

5

8

16

6

V

.. .. ,.1

~

Jl~

..

~

1

.

8

9

10

11 min.

GCJF01043

B. Rxi®-SSii MS

14

3

9,10 1112 15

18

20 19

4

13

8

16

5

7

I

I

!

I

6

,II A

I

I I

17

10 11 12 13 14 15

16 17 18 19 20 21 22 23 24 25min.

GC_FF01044

Column:

Rt -CLPesticides2,30m,

0.25mm

10,

0,20llm

(cat.# 11323)

Sample:

10llg/mL

Organochlorine Pesticide

Mix AB# 3 (cat.# 32415)

inolive oil

Inj.:

l!JL,splitless(hold 0.5min.),

3.5mm single gooseneckliner

(cat.# 20962) packedwithwool

Inj.

ternp.:

225' C

Carrier gas:

helium, constant flow

Flowrate:

I rnt/rnin,

Oventemp.:

140'C(hold 0.5min.) to 268' C

@

20°C/min,to 290°C

@

3' C

/min.to

330' C(hold 5

rnin.)

@

20' C/ min.

Del:

MS

Transfer line temp.: 320°C

Ionization:

EI

Mode:

SIM

Compound

Quant. ion

*1.a -BHC

219

2.y-BHC

219

3.

~-BHC

219

4.8-BHC

219

5. heptachlor

272

6.aldrin

263

7. heptachlor epoxide 263

8.y-chlordane

272

9.a-chlordane

272

10. endosulfan I

195

11.4,4'-DDE

246

12. dieldrin

79

13. endrin

263

14. 4,4'-DDD

235

15.endosulfanII

195

16. 4,4'-DDT

235

17, endrinaldehyde

67

18.endosulfansulfate 272

19. methoxychlor

227

20. endrin ketone

67

* notpresent

Ql

181

181

181

181

237

293

237

237

237

207

318

263

281

165

207

165

250

229

274

317

Global RESTEKAdvantage

· 9·

comparable to conventional SPE- without the necessi­

ty of vacuum manifolds or high pressure systems. The

GPC method attained recoveries of > 95%. However

this method requires large amounts of solvent and

takes over twice as long as other method s.

The dSPE method shown here is an efficient, cost­

effective way to clean up chlorinated pesticide

residues in olive oil. With good recoveries and mini mal matrix interference, it is an easy way to reduce

solvent usage, compared to conventional SPE, and is

more cost-effective than GPc.

References

1. C. Lentza-Rizos, E.J. Avramides, Rev. Environ. Contam.Toxicol, 141(1995)

111.

2. S, Cunha, S. Lehotay,

K.

Mastovska, J. Sep.Sci. 30(2007) 620.

3. M. Crawford, M. Halvorson, J. Stevens,The Examination andAutomation

ofGPC, 5PEandQuEChERSUtilized in ExtractingPesticides fromOlive Oil.

HPLC2008poster presentation.

Product Listing

dSPE Tube for Clean-Up of Pesticide Residue

Samples

Description

2mLMicro-Ce

Material

ntrifugeTubes fo

Methods

r dSPE

qty.

cat#

Resprep

Q250

150mg MgSO"

50mgPSA

AOAC2007,1

100-pk. 26124

PSA-primary and secondary amine exchange material.

Organochlorine Pesticide Mix AB

#

3

(20

components)

aldrin

dieldrin

a -BHC

endosulfan

I

P-BHC

endosulfan

II

o-BHC

endosulfan sulfate

y-BHC (lindane)

endrin

a -chlordane

endrin aldehyde

y-chlordane

endrin ketone

4,4'-000

heptachlor

4,4'-00E

heptachlor epoxide (isomer B)

4,4'-00T

methoxychlor

2,00011g/ mL

each in hexane:toluene (1:1), ImL/ ampul

cat. # 32415 ea.

Rtx®-CLPesticides2 Columns (fused silica)

ID

df

{J.Jm)

temp.limits

length cat. #

0.25mm 0,20 -60 to

320/340' C

30-Meter 11323

Rxi®-SSii MS Columns (fused silica)

(Crossbond" , selectivity close to 5%diphenyl/ 95%dimethyl polysiloxane)

ID

df

{J.Jm)

temp. limits

length cat. #

0.25mm 0,25 -60 to

330/350'C

30-Meter 13623

For more SPE products, please

visit us at

www.restek.com

or

contact your local

Restek representative.

www.restek.com

Q3

109

109

109

109

100

220

81

65

65

241

176

277

81

199

199

345

239

281

Website :

www.chromtech.net.au

E-mail :

info@chromatech.net.au

TelNo : 03 9762 2034 . . . in AUSTRALIA