Increase Sample

Throughput for

Complex Drinking

Water Pesticides

Continued from page 1.

EPA Method 508.1 includes many of the components

as Method 505, a simi lar

GC/ECD

method, but also

contains several others, expanding the list to 38 com­

pounds. Thi s method calls for solid phase extraction

and extract concentra tion , followed by an alysis using

a

GC/ECD

system. In order to increase sample

th roughp ut , an op timized method was developed

using a dual column configuration wit h th e Rtx®Cl.Pesticides/Rtxw-C l.Pesticides z column pair. These

columns, used und er the conditions shown, offer a

unique selectivity th at allows the target analytes to be

resolved in ap p roximately half the analysis time of th e

origina l me tho d (Figure

1).

There was one coelution

on th e primary column, but these compounds were

sepa rated on th e second column. Both columns easi­

ly passed the comprehensive system performan ce cri­

teria adapted from 508. 1 (Table 1).'

In conclusion, due to th e complexity of th e com­

pound list in Meth od 508.1, a very high degree of

selectivity is required of the capillary column in order

to achieve ade qu ate reso lution of all target analytes in

a reasonable time. The op timized d ual colum n

method shown here offers a significantly faster analy­

sis tim e, while ma inta ining excellent reso lution of

challenging drinking water pesticide s and herbicides.

References

1. http:/ /www.usda.gov/ nass/ pubs/trackrec/ trackOOa.htm#principaI

2. USEPA Method 508.1, JamesWEichelberger Rev 1.01994.

Conditions for Figure 1

Column:

Sample:

Inj.:

Inj. temp.:

Carrier gas:

Linear velocity:

Oventemp.:

Detector temp.:

Rtx®-CLPesticides2,

30~0.32mm!D,

0.251lm

(cat.# 11324)and

Rtx -CLPesticides,

30m, 0.32mm!D,0.3&,m (cat.# 11141) with

5m

x

0.32mm!D Rxi deactivated guard tubing

(cat.# 1003cW, connectedusing Universal

"Y"

Press-Tight

R

Connector (cat.# 20405-261)

50ng/mL 508.1 CalibrationMix# 1 (cat.# 32094),

100ng/mL 508.1CalibrationMix#2 (cat.# 32095),

100ng/ mL508.1 CalibrationMix #3 (cat.# 32096),

50ng/mL508.1 Internal Standard (cat.# 32091),

250ng/ mL508.1 Surrogate (cat.# 32092),

500ng/ mLAtrazine(cat.# 32208),

500ng/ mLSimazine (cat.# 32236) in ethyl acetate

2IlLsplitless (hold 0.75 min.), 4mmcycledouble

gooseneck liner (cat.# 20896)

250°C

helium, constant flow

26cm/ sec. @ 80'C

80'C (hold 0.5 min.)to 155'C(hold 1 min.) @

19' C/min. to 210' C@ 4'C/min. to 3WOC

(hold 0.5 min.) @ 25°C/ min.

ECD @ 32S

c

C

Figure 1

Resolve all critical pairs using Rtx®-CLPesticides and

Rtx®-CLPesticides2 columns.

27.4,4'-DDE

1. hexachlorocyclopentadiene

14. heptachlor

28. dieldrin

2. etridiazole

15. chlorothalonil

29. endrin

3. chlorneb

16. metribuzin

-

6

23 25

2 28

29 3132

7

26

11

1

J

J

~ lt

1

0

"!i ii i i i i ii i ii i

i i i i i i i ii

ii i

I '

I

2d.o

I

~o

13.0

~o

0

I

,-1,

1

2

21

I

1

16

14

17,18

I

i

6

19

i

12

I

i

i

2~

I

4. propachlor

17. alachlor

5. trifluralin

18. aldrin

6.

hexachlorobenzene

19. 4,4'-dibromobiphenyl (55)

7. a -BHC

20. metachlor

8. simazine

21. DCPA

9. atrazine

22. heptachlor epoxide

10. pentachloronitrobenzene (IS)

23. y-chlordane

11.y-BHC

24. cyanazine

12. P-BHC

25. a -chlordane

13.

i)-BHC

26. endosulfanI

Rtx"'-CLPesticides2

I

I

I

I

I

i

I

I

I

I

I

I

I

10

GCEVOl023

30. cnlorobenzilate

31.4,4'-DDD

32. endosulfanII

33. 4,4'-DDT

34. endrin aldehyde

35. endosulfansulfate

36. methoxychlor

37. cis-permethrin

38. trans-permethrin

33

34

22.0

37

,~

,

I

,

, ,

I

i

min.

Ido

Rtx"'-CLPesticides

28

29 31 32

27

1

7

11

2

6

10

Vi

,J

30

~

8

~

'--~

~

~

II I I i i i

I

I i

I

I I I I I i I

I '

I i I

I ' ,,,,,,,

id

.~

,,,,,,,

iL~

,,

'I

20.0

21.0

23

25

I

3 3

2

13

16,14

15

21

I

34

18

I

20,22

3

19

I

3

1

3

lY

37

I

I

I

10

'~

'LLJ

www.restek.com

• 2 •

Website :

www.chromtech.net.au

E-mail :

info@chromatech.net.au