Figure2
Allure
PFPPropyl column baseline separates cocaine (COC) and its metabolite,
ecgoninemethyl ester (EME), with excellent peak shape in less than fiveminutes.
0
1
2
3
4
5
6
7
8
9 min.
1
2
3
4
5
RestekCorporation • (800)356-1688 • (814)353-1300
Data Courtesy of Shane Needham, Pfizer Inc
Column:
Allure
PFPPropyl
Catalog#:
9169532
Dimensions:
30mmx2.1mm
Particle size:
5µm
Pore size:
60Å
Conditions:
Mobile phase:
5mMpH3.0
ammonium formate:
acetonitrile (10:90)
Flow:
0.6mL/min.
Column temp.:
ambient
Det.:
PE/SciexAPI 3000
Interface:
Turbo IonSpray,ESI
Interface temp.:
150°C
Ion mode:
positive
ESI probe voltage:
5000V
Orifice:
+/-71V
Ring:
+/- 265V
Collision gas:
Nitrogen
Collision gas pressure:
2.2mTorr
Collision gas energy(COC): 28eV
Collision gas energy(EME): 26eV
Electron multiplier:
2100 volts
Auxillary gas flow:
7000cc/min.
Nebulizer gas setting:
15lb/in.
2
Curtain gas setting:
12lb/in.
2
PeakList:
1. EME (ecgoninemethyl ester)
2.COC (cocaine)
SampleConditions:
Inj.:
10µL
Conc.:
1µg/mL
Solvent:
water
Temp.:
4°C
LC_0126
1
2
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5 min.
XICof +MRM (3pairs) for 304.0 / 182.0 amu
2.35e3 cps
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5 min.
XICof +MRM (3pairs) for 200.0 / 182.0 amu
1.30e3 cps
12x increase
inCOC response
over C18
LC_0137
PeakList:
1. cytosine
2. uracil
3. guanine
4. thymine
5. adenine
Sample:
Inj.:
1.0 mL
Conc.
100µg/mL
Solvent:
20mMAmmonium
Acetate,pH5.0.
Ammonium hydroxide
added to keep guanine
in solution
Column:
Allure
PFPPropyl
Catalog #:
9169565
Dimensions:
150 x 4.6mm
Particle Size: 5µm
PoreSize:
60Å
Conditions:
Mobile Phase: 20mMAmmonium
Acetate, pH5.0:
Methanol (85:15, v/v)
Flow:
1.0mL/min
Temp.:
ambient
Det.:
UV@260nm
Figure3
Nucleic bases as guanine, cytosine, uradine, thymine, and adenine are all easily retained upon the Allure
PFPPropyl.
Therefore, Restek’s Allure
PFP Propyl and Ultra PFP columns
are the best choice for the analysis of basic analytes. COC,
EME, quinine, morphine, beta-blockers, and tricyclic antide-
pressants have been analyzed successfully in urine, blood, and
tissue samples. In addition, pyridines, pyrimidines, and multi-
halogenated compounds have been successfully separated on
the Ultra PFP column.
The Allure
PFP Propyl and Ultra PFP columns provide
superior retention and peak shape for analytes having a pKa
>8 without the need for modifers, and they can provide
increased sensitivity for LC/MS ESI due to the high level of
organic solvent used in the mobile phase.