Figure 5
Analytical system designed to detect losses
from a 17ppbv standard.
1mL Sulfinert
sample loop
exit
orifice = 0.0060”
analytical column
SCD
Sulfinert™
sample cylinder
Sulfinert
valve
Rtx
®
-1CapillaryColumns (FusedSilica)
(Crossbond
®
100% dimethyl polysiloxane)
Themaximum temperatures listed are for 15- and 30-meter lengths.
Longer lengthsmay have a slightly reducedmaximum temperature.
R
t-XLSulfur
MicropackedColumns
Other column dimensions can be prepared on a custom basis. Please inquire.
Purchase installation kit separately.
ID
df (µm)
temp. limits
15m 30m 60m 75m 105m
0.32mm 3.00 -60 to 280/300°C 10181 10184 10187
10190
4.00 -60 to 280/300°C
10198
5.00 -60 to 260/280°C 10176 10178 10180
0.45mm 2.55 -60 to 270/290°C
10992
0.53mm 3.00 -60 to 270/290°C 10182 10185 10188
10189
5.00 -60 to 270/290°C 10177 10179 10183
10194
7.00 -60 to 240/260°C 10191 10192 10193
sulfur compounds.Alternatively, a 30-meter, 0.32mm ID, 4µm
Rtx
®
-1 column can be used to analyze highermolecular weight
sulfur compounds, such as thiophenes (Figure 2).
Another excellent approach for analyzing lowmolecular
weight sulfur compounds is the use ofmicropacked columns.
TheRt-XLSulfur
micropacked column contains a specially
deactivated divinylbenzene porous polymer in stainless steel
tubing, deactivated throughRestek’s state-of-the-art Sulfinert
passivation process. The inertness of both the packingmaterial
and the tubing ensure a column that is capable of analyzing
active sulfur compounds to 10ppb.Moreover, theRt-XLSulfur
micropacked column displaysminimal bleed, well within limits
necessary for ppb-level sulfur analysis, after a brief condition-
ing period (<30minutes). Themaximum temperature limit,
310°C, allows rapid elution of the highermolecular weight
analytes. This column achieves the critical separation of hydro-
gen sulfide (H
2
S), carbonyl sulfide (COS), and sulfur dioxide
(SO
2
), as defined in the International Society of Beverage
Technologists (ISBT) Procedure 14.0. Figure 3 shows the high-
ly volatileH
2
S andCOS separated using a 1-meter, 0.75mm ID
Rt-XLSulfur
micropacked column.Additionally, these volatile
sulfur compounds arewell-retained andwell-resolved from the
hydrocarbons that could interferewith quantification on some
sulfur-specific detectors (Figure 4).
Note that to achieve this high level of sensitivity, every compo-
nent of the sample pathwaymust be inert: the porous polymer,
the column tubing, the column end fittings, and, additionally,
the sample loop and/or inlet sleeve. Sample pathways in the
analyses shown in Figures 1 through 4were passivated using
Restek’s Sulfinert
deactivation process. Figure 5 shows a
schematic diagram of a system designed to analyze volatile and
reactive sulfur compounds. From the Sulfinert
-treated sample
cylinder used to collect and store the sample, to the Sulfinert
-
treated valve and sample loop used to transfer the sample to the
GC system, to either the inert capillary or packed column,
Restek offers a complete line of products to ensure consistent
and reliable analysis of sulfur compounds.
Formore information about the Sulfinert
passivation tech-
nique, request a copy of Restek’s brochure on Sulfinert
coat-
ings (Lit. cat.# 59203).
*0.020" wall thickness
Sulfinert
Welded 304Grade Stainless SteelTubing
Available in lengths from 5—400 feet. Call for details.
**0.035" wall thickness
Sulfinert
Seamless 316Grade Stainless SteelTubing
Available in lengths from 5—400 feet. Call for details.
ID
OD
cat.#
0.055" (1.40mm)
1
/
8
" (3.18mm)**
22508
0.180" (4.57mm)
1
/
4
" (6.35mm)**
22509
OD
ID (mm)
1-Meter
2-Meter
1
/
16
1.0mm
19804
19805
0.95mm
0.75mm
19806
19807
for 0.75mm ID col.
for 1mm ID col.
for 2mm ID col.
For valve applications
21062
21065
21067
For split applications
21063
For all Agilent GCs
21064
For direct injections
21066
InstallationKits
ID
OD
cat.#
0.011” (0.28mm)
0.022” (0.56mm)
22500
0.021” (0.53mm)
0.029” (0.74mm)
22501
0.010” (0.25mm)
1
/
16
” (1.59mm)
22502
0.020” (0.51mm)
1
/
16
” (1.59mm)
22503
0.030” (0.76mm)
1
/
16
” (1.59mm)
22504
0.040” (1.02mm)
1
/
16
” (1.59mm)
22505
0.085” (2.16mm)
1
/
8
” (3.18mm)*
22506
0.210” (5.33mm)
1
/
4
” (6.35mm)*
22507
Sulfinert
-TreatedSampleCylinders
• Sizes from 75cc to 2250cc.
• Durable 316 stainless steel.
• 1/4-inch femaleNPT threaded ends.
• D.O.T. rated to 1800psi at room temperature.
Size
qty.
cat.#
75cc
ea.
24130
150cc
ea.
24131
300cc
ea.
24132
500cc
ea.
24133
1000cc
ea.
24134
2250cc
ea.
21394
1...,223,224,225,226,227,228,229,230,231,232 234,235,236,237,238,239,240,241,242,243,...324