restekapp07 - page 120

Stability
A 55ppbv reference standard (11ppbv each sulfur compound, dry standard)
was analyzed three times each day for six days. Eighteen SilcoCan
canisters
and two electropolished canisters were used. The sulfurVOCs showed excel-
lent stability in the SilcoCan
canisters. The electropolished canisters allowed
rapiddegradationof hydrogen sulfide,methylmercaptan, and ethylmercap-
tan (Figure 1).
HumidityEffects
Five SilcoCan
canisters that were used in the stability test were cleaned
according to US Environmental Protection Agency (EPA) Compendium of
Toxic Organic Method TO-14 and reused for the humidity study.
3
After
adding 100µL of deionized H
2
O to each canister, the relative humidity was
50%. Two mL of the stock sulfur standard was added to each canister and
aliquotswereanalyzedover sixdays (Figure1).The results shownodifference
in the performance by the SilcoCan
canisters for storing humidified sulfur
VOCs as compared todry standards.
Conclusion
This study confirmed the stability of very low-level sulfurVOCs (1-20ppbv)
inSilcoCan
canisters.Usingdryorhumidifiedconditions, sulfurcompounds
exhibitedvirtuallyno loss inSilcoCan
canisters after sixdays. Samplingwith
electropolished canisters leads to degradation of hydrogen disulfide, methyl
mercaptan, and ethylmercaptan.
References
1.QuangTran, You-ZhiTang;
Stability of Reduced Sulfur Compounds inWholeAir Samplers
, 1994
AWMA/EPA International Symposium ofMeasurement ofToxic andRelatedAir Pollutants.
2. Hoyt, Steven; Longacre, Vivian; and Stroupe, Michale;
Measurement of OxygenatedHydrocarbons
andReduced Sulfur Gases by Full ScanGC/MS: EPA TO-14
in:
Sampling andAnalysis of Airborne
Pollutants
, EricWinegar, and LawrenceKeith, editors. CRCPress, 1993 384pp (Restek cat.#20468).
3. MethodTO-14A,
Determination of VolatileOrganic Compounds (VOCs) inAmbient Air Using
Specially PreparedCanisterswith Subsequent Analysis byGas Chromatography
in:
Compendium of
Methods for theDetermination of ToxicOrganic Compounds inAmbient Air
. US EPA, Jan 1997.
References 1 and 3 not available fromRestek.
Table1
Concentrationsof sulfur compoundsused in stability study.
Stock Conc.
Standard Conc.
Standard Conc.
Compound
(ppmv)
(ppbv)
as Sulfur (ppbv)
hydrogen sulfide (H
2
S)
105
11.51
10.83
carbonyl sulfide (COS)
98
10.74
5.73
methyl mercaptan (CH
3
SH)
101
11.07
7.38
ethyl mercaptan (CH
3
CH
2
SH)
101
11.07
5.71
dimethylsulfide (CH
3
SCH
3
)
99
10.85
6.81
dimethyldisulfide (CH
3
SSCH
3
)
100
10.96
7.46
Internal standard
Figure2
Rtx®-1 column is ideal for trace-level sulfur analysis.
1. hydrogen sulfide
2. carbonyl sulfide
3. methyl mercaptan
4. ethyl mercaptan
5. dimethyl sulfide
6. dimethyl disulfide
Rtx
®
-1 60m, 0.53mm ID, 7.0µm (cat.# 10193)
Oven temp.:
30°C (hold 1min.) to
180°C@ 10°C/min. (hold 5min.)
Carrier gas:
helium
Flow rate:
8.5mL/min.
1
2
3
4
6
5
min.
5
GC_AR00477
For other Rtx
®
-1 column dimensions, please request our general
catalog or visit ourwebsite.
Rtx
®
-1Column (fusedsilica)
(Crossbond
®
100% dimethyl polysiloxane)
ID df (µm)
temp. limits
length
cat.#
0.32mm 4.00 -60 to 280/300°C 30-Meter
10198
0.53mm 7.00 -60 to 240/260°C 60-Meter
10193
Rt-XLSulfur
PackedColumns
Purchase installation kit separately. Please see our catalog.
*Please add configuration suffix number to cat.#when ordering.
Please see our catalog.
OD
ID (mm)
1-Meter*
2-Meter*
1
/
8
"
2.0mm
80484-
80485-
3
/
16
"*
3.2mm
80482-
80483-
Rt-XLSulfur
MicropackedColumns
Purchase installation kit separately. Please see our catalog.
OD
ID (mm)
1-Meter
2-Meter
1
/
16
"
1.0mm
19804
19805
0.95mm
0.75mm
19806
19807
Rt-XLSulfur™Packed/Micropacked
Columns
• Optimized for lowpbbv sulfur analyses.
• Eliminate theneed forTeflon
®
tubing.
• Column and end-fittings are Sulfinert
®
-treated
formaximum inertness.
1...,110,111,112,113,114,115,116,117,118,119 121,122,123,124,125,126,127,128,129,130,...324