MRC-2013-Catalog - page 222

222
E
ELECTROPHORESIS
Maxi Systems
ME-26-16-24-32, Maxi Plus Horizontal Gel Electrophoresis System
ME-26-16-24-32 is designed for rapid screening of very large numbers of cloning or PCR samples, and it has the
maximum capacity of 672 samples per gel. This allows loading and analysis of exactly seven 96 well format micro titer
plates. The large gel run length of 32cm also allows resolution of samples over a long distance for separation of
complex sample bands such as in restriction fragment analysis. Maxi-plus is available with a full length tray or with other
tray length options of 16 or 24cm so that user’s exact requirements can be matched.
ME-20-10-20/ME-20-25, Maxi Horizontal Gel Electrophoresis System
Maxi is primarily designed for resolution of high numbers of samples as in cloning or PCR experiments. Maxi allows ultra
high-resolution separations over extended runs. Tray sizes correspond to standard blotter sizes. It also allows for easy
ME-20-10-20
ME-26-16-24-32
sample transfer onto a membrane for further analysis. Three
tray sizes are available, 20 x 20cm, 20 x 25cm and 20 x
10cm. Multi-channel Pipette compatible combs for up to
40 samples each facilitate speed loading of up to 440
samples per gel. 50 sample combs (not multi-channel
Pipette compatible) allow maximum sample capability of
550 samples per gel.
Features:
Low buffer consumption.
Single molded tank.
Three tray options available.
Multi-channel Pipette compatibility.
Great indications for gel making and running.
Up to 450 samples per tray.
No tapes, clamps or springs needed.
Model
ME-20-10-20
ME-20-25
Unit dimension (WxLxH)
395x230x90mm
Gel dimension (WxL)
200x100mm, 200x200mm
200x250mm
Maximum sample
200 for 200x100mm tray,
450 for 200x200mm tray
550 for 200x250mm tray
Buffer volume
1200ml
Construction
Injection molded construction durable, leak proof environment for complete safety and long life
Cassette type electrodes
Inexpensive, easy to replace, made of 99.99% corrosion resistant pure platinum
Electrical safety
Lid can be located in one way only, on removal- power is disconnected from buffer chamber
Rapid casting gel
Use casting dams
Model
ME-26-16-24-32
Unit dimension (WxLxH)
500x280x90mm
Gel dimension (WxL)
260x160mm, 260x240mm, 260x320mm
Maximum sample
336 for 260x160mm tray, 504 for 260x240mm tray, 672 for 260x320mm tray
Buffer volume
1400ml
Construction
Injection molded construction durable, leak proof environment for complete safety and long life
Cassette type electrodes
Inexpensive, easy to replace, made of 99.99% corrosion resistant pure platinum
Electrical safety
Lid can be located in one way only, on removal- power is disconnected from buffer chamber
Rapid casting gel
Casting dam
In addition to options for single length gel trays, Maxi-plus is
available with all three gel tray lengths to provide the
maximum in flexibility, versatility and value.
Buffer recirculation ports are included as standard to allow
enhanced resolution over extended runs while loading
guides enhance well visibility for easy sample loading.
Features:
Low buffer consumption.
Single molded tank.
Three tray options available.
Multi-channel Pipette compatibility.
Great indications for gel making & running.
Up to 672 samples per tray.
No tapes, clamps or springs needed