MRC-2013-Catalog - page 213

213
ELECTRONICS
E
Range
Resolution
Accuracy
0.000 to 9.999 KW *0.001/0.01/0.1 KW ± (1%+0.008 KW)
10.00 to 99.99 KW *0.01/0.1 KW ± (1%+0.08 KW)
100.0 to 999.9 KW 0.1 KW ± (1%+0.8 KW)
1.000 to 9.999 MW 0.001 MW ± (1%+0.008 MW)
Range
Resolution
Accuracy
0.000 to 9.999 KVA *0.001/0.01/0.1 KVA ± (1%+0.008 KVA)
10.00 to 99.99 KVA *0.01/0.1 KVA ± (1%+0.08 KVA)
100.0 to 999.9 KVA
0.1 KVA
± (1%+0.8 KVA)
1.000 to 9.999 MVA 0.001 MVA ± (1%+0.008 MVA)
Range
Resolution
Accuracy
0.000 to 9.999 KVAR *0.001/0.01/0.1 KVAR ± (1%+0.008 KVAR)
10.00 to 99.99 KVAR *0.01/0.1 KVAR ± (1%+0.08 KVAR)
100.0 to 999.9 KVAR
0.1 KVAR
± (1%+0.8 KVAR)
1.000 to 9.999 MVAR 0.001 MVAR ± (1%+0.008 MVAR)
Range
Resolution
Accuracy
0.000 to 9.999 KWH 0.001 KWH
± (2%+0.008 KWH)
10.00 to 99.99 KWH
0.01 KWH
± (2%+0.08 KWH)
100.0 to 999.9 KWH
0.1 KWH
± (2%+0.8 KWH)
1.000 to 9.999 MWH 0.001 MWH ± (2%+0.008 MWH)
Range
Resolution
Accuracy
0.000 to 9.999 KVAH 0.001 KVAH ± (2%+0.008 KVAH)
10.00 to 99.99 KVAH 0.01 KVAH
± (2%+0.08 KVAH)
100.0 to 999.9 KVAH 0.1 KVAH
± (2%+0.8 KVAH)
1.000 to 9.999 MVAH 0.001 MVAH ± (2%+0.008 MVAH)
Range
Resolution
Accuracy
0.000 to 9.999 KVARH 0.001 KVARH ± (2%+0.008 KVARH)
10.00 to 99.99 KVARH 0.01 KVARH ± (2%+0.08 KVARH)
100.0 to 999.9 KVARH 0.1 KVARH
± (2%+0.8 KVARH)
1.000 to 9.999 MVARH 0.001 MVARH ± (2%+0.008 MVARH)
Electrical Specifications (23±5
°
C):
Range
Resolution
Accuracy
10.0V to 600.0V
* Phase to neutral line
0.1V
± (0.5%+0.5V)
10.0V to 600.0V
* Phase to phase
ACV
Active (Real) Power Active (Real) Power
Apparent Power
Reactive Power
Watt Hour (Active Power Hour): WH
VA Hour (Apparent Power Hour): SH
VAR Hour (Reactive Power Hour): QH
Range
Resolution
Accuracy
20A
0.001A, < 10 A
± (0.5%+0.1A)
0.01A,
10 A
200A
0.01A, < 100 A
± (0.5%+0.5A)
0.1A,
100 A
1200A
0.1A, < 1000 A
± (0.5%+5A)
1A,
1000 A
ACA
Range
Resolution
Accuracy
0.00 to 1.00
0.01
±0.04
Remark:
* PFH: Long term average power factor (WH/SH)
* PF
Σ
:
For 3
Φ
4W, 3
Φ
3W For 1
Φ
3W
PF
Σ
= ( PF1 + PF2 + PF3 )/3 PF
Σ
= ( PF1 + PF2 )/2
Power factor
Range
Resolution
Accuracy
-180° to 180°
0.1°
± 1° * ACOS(PF)
Φ
( Phase angle )
Range
Resolution
Accuracy
45 to 65 Hz
0.1 Hz
0.1 Hz
Frequency
3 Phase Power Analyzer