206
ELECTRONICS
Insulation Tester, Multimeter
MEG OHMS
OHMS
Continuity Beeper
AC Voltage (40Hz-500Hz)
●
2000M W /1000V, 200M W /500V, 200M W /250V.
●
Power lock for 3 minutes (Auto power off).
●
Auto-Zero adjustment.
●
Data-Hold-Function.
●
Digital readout easy to obtain by 0.65" LCD display.
●
Automatic unit & sign annunciator.
●
Rotary switch easy for range selection.
●
Continuity beeper.
●
Battery operated/Overload Protection.
●
Safety test leads.
●
ImA test current.
TES-1600, Insulation Tester
General Specifications
Display
3.5 digit 0.65" large LCD
Sampling rate (AID)
2.5 time/sec
Zero adjustment
Automatically
Operating temp.
& Storage Environment
0°C-40°C <80% R.H.
-10°C to 60°C <70% R.H.
Power source
6 'AA' 1.5V batteries
Dimension
165(L)x 100(W)x57(H) mm
Weight
500g
Accessories
Test leads, 6pcs. of battery, carrying case and manual
Range
Resolution
Accuracy
Terminal Voltage
Test Current
200 M
Ω
/250V
0.1 M
Ω
±(3% of rdg + 3dgts)
250V+10%
1mA at 250K
Ω
load
200 M
Ω
/500V
0.1 M
Ω
500V+10%
1mA at 500K
Ω
load
2000 M
Ω
/1000V
1 M
Ω
1000V+10%
1mA at 1 M
Ω
load
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
200
Ω
0.1
Ω
± (1% of rdg + 2dgts)
3.3V
500V DC/AC
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
200
Ω
0.1
Ω
Resistance < 100
Ω
3.3V
500V DC/AC
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
750V
1V
± (0.8% of rdg+3dgts)
10 M
Ω
1100 VCD & 800 VAC
DM-9680 KITS, multimeter, kits, RS232 cable+ software+ carrying case
●
Multi function measurement : ACV, DCV, ACA, DCA, OHM,
Continuity Beeper, Transistor hFE, Diode,
●
Meet IEC safety requirement.
●
High accuracy in measuring.
●
High internal impedance assures minimum measuring error.
●
Rotary function switch, easy operation.
●
Large size LCD display, easy reading.
●
LCD display, clear readout even in high ambient light environment.
●
Compact, light weight & excellent operativeness.
●
Overload protection for any range.
●
Drop proof.
●
RS232 PC interface, photo couple isolated circuit.
●
When apply the optional software, then the meter can be used as
data logging, data recorder & other intelligent applications.
CA-06
UPCB-02
SW-U801-WIN
A continuity test beeper is standard, when checking short or open circuit, it
is not necessary to look at the meter. The beeper sounds if continuity is
present.
0 - 1000 hFE values of either p.n.p. or n.p.n. transistor.
(Test condition: base dc current approx. 10 uA, VCE: approx. 2.8 V).
Isolated (photo couple) RS-232 serial data output, 9600 baud rate.
Continuity Beeper
Transistor hFE Meansurement
RS-232 Output
TES-1600