MRC-2013-Catalog - page 206

206
ELECTRONICS
Insulation Tester, Multimeter
MEG OHMS
OHMS
Continuity Beeper
AC Voltage (40Hz-500Hz)
2000M W /1000V, 200M W /500V, 200M W /250V.
Power lock for 3 minutes (Auto power off).
Auto-Zero adjustment.
Data-Hold-Function.
Digital readout easy to obtain by 0.65" LCD display.
Automatic unit & sign annunciator.
Rotary switch easy for range selection.
Continuity beeper.
Battery operated/Overload Protection.
Safety test leads.
ImA test current.
TES-1600, Insulation Tester
General Specifications
Display
3.5 digit 0.65" large LCD
Sampling rate (AID)
2.5 time/sec
Zero adjustment
Automatically
Operating temp.
& Storage Environment
0°C-40°C <80% R.H.
-10°C to 60°C <70% R.H.
Power source
6 'AA' 1.5V batteries
Dimension
165(L)x 100(W)x57(H) mm
Weight
500g
Accessories
Test leads, 6pcs. of battery, carrying case and manual
Range
Resolution
Accuracy
Terminal Voltage
Test Current
200 M
Ω
/250V
0.1 M
Ω
±(3% of rdg + 3dgts)
250V+10%
1mA at 250K
Ω
load
200 M
Ω
/500V
0.1 M
Ω
500V+10%
1mA at 500K
Ω
load
2000 M
Ω
/1000V
1 M
Ω
1000V+10%
1mA at 1 M
Ω
load
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
200
Ω
0.1
Ω
± (1% of rdg + 2dgts)
3.3V
500V DC/AC
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
200
Ω
0.1
Ω
Resistance < 100
Ω
3.3V
500V DC/AC
Range
Resolution
Accuracy
Max. Open Circuit Voltage Overload Protection
750V
1V
± (0.8% of rdg+3dgts)
10 M
Ω
1100 VCD & 800 VAC
DM-9680 KITS, multimeter, kits, RS232 cable+ software+ carrying case
Multi function measurement : ACV, DCV, ACA, DCA, OHM,
Continuity Beeper, Transistor hFE, Diode,
Meet IEC safety requirement.
High accuracy in measuring.
High internal impedance assures minimum measuring error.
Rotary function switch, easy operation.
Large size LCD display, easy reading.
LCD display, clear readout even in high ambient light environment.
Compact, light weight & excellent operativeness.
Overload protection for any range.
Drop proof.
RS232 PC interface, photo couple isolated circuit.
When apply the optional software, then the meter can be used as
data logging, data recorder & other intelligent applications.
CA-06
UPCB-02
SW-U801-WIN
A continuity test beeper is standard, when checking short or open circuit, it
is not necessary to look at the meter. The beeper sounds if continuity is
present.
0 - 1000 hFE values of either p.n.p. or n.p.n. transistor.
(Test condition: base dc current approx. 10 uA, VCE: approx. 2.8 V).
Isolated (photo couple) RS-232 serial data output, 9600 baud rate.
Continuity Beeper
Transistor hFE Meansurement
RS-232 Output
TES-1600
E
1...,196,197,198,199,200,201,202,203,204,205 207,208,209,210,211,212,213,214,215,216,...738