MRC-2013-Catalog - page 207

207
ELECTRONICS
E
Model
DM-9680 KITS
Display
18 mm (0.7") LCD, 3 1/2 digits.
Measurement & Function
DCV, ACV, DCA, ACA, ohms, hFE, Continuity Beeper.
Polarity
Automatic Switching, '-' indicates negative polarity.
Zero Adj.
Automatic
Over-input
Display shows '1' or '-1'.
Sampling Time
Approx. 0.4 second.
RS-232 Output
Isolated (photo couple) RS-232 serial data output, 9600 baud rate.
Operating Humidity
Less than 80% R.H.
Operating Temp.
0°C to 50°C (32°F to 122°F)
Power Supply
006P DC 9V battery (heavy duty).
Power Current
Approx. DC 7 mA.
Weight
322 g/0.71 LB.
Dimension
204 x 90 x 36 mm (7.3 x 3.4 x 1.5 inch).
Accessories Included
 * Instruction manual: 1PC * Hard Carrying case, CA-06 * 0.5 Amp Spare Fuse: 1 PC * Red and
Black Test Leads: 1 Pair * RS-232 cable: UPCB-02 * Application Software: SW-U801-WIN
optional Accessories
* RS232 cable, UPCB-02 * USB cable, USB-01 * Light adapter LX-02 * Anemometer adapter, AM-402
* Tachometer adapter TA-601 * 1000 A DC/AC current adapter, CA-501 * 1000 A DC/AC current
adapter, CA-502 * 2000 A DC/AC current adapter, CA-203 * Mini ACA current adapter, CA-201
* Pressure adapter, PS-403 * EMF adapter, EMF-824 * Sound adapter, SL-406 * 50 A current
shunt, ST-50 * High voltage probe, HV-40 * Soft carrying case CA-03, CA-05A
* Alligator test lead, TL-02S * Heavy duty alligators, AL-04 * Holster, HS-01
Range
Accuracy
Resolution Input Impedance Overload CKT. Protection
200mV
± (0.5%+1d)
100uV
10 M ohm
500V DC, 350V AC, 15 secs
2V
± (0.8%+1d)
1mV
DC 1000V
AC 800 V
15 secs
20V
10mV
200V
100mV
1000V
1V
Range
Accuracy
Resolution Input Impedance Overload CKT. Protection
200mV
± (1%+2d)
100uV
10 M ohm
500V DC, 350V AC, 15 secs
2V
1mV
DC 1000V
AC 800 V
15 secs
20V
10mV
200V
100mV
750V
1V
Electrical Specifications (23±5
°
C):
DC Voltage
AC Voltage, Freq. Response: 40Hz-500Hz, sine wave spec. tested on 60Hz/50Hz
Range (ohm)
Accuracy
Resolution Open CKT. Voltage Overload CKT. Protection
200
± (1%+3d)
0.1 ohm
Approx. 3V
AC/DC 500V
2K
± (0.8%+1d)
1 ohm
Approx. 0.3V Max.
20K
10 ohm
200K
100 ohm
2M
1k ohm
20M
± (2%+2d)
10K ohm
Range
Accuracy
Resolution Voltage Drop in F.S.
Overload CKT. Protection
200uA
± (1%+1d)
0.1uA
DC 200 mV
0.5 A Fuse
2mA
1uA
20mA
10uA
200mA
100uA
A*
10mA
Un Fused
* A range: 0 t0 10 A - continuous operation > 10 A to 20 A - 1 min. operation max.
Range
Accuracy
Resolution Voltage Drop in F.S.
Overload CKT. Protection
200uA
± (1%+1d)
0.1uA
AC 200 mV
0.5 A Fuse
2mA
1uA
20mA
10uA
200mA
100uA
A*
10mA
Un Fused
* A range: 0 t0 10 A - continuous operation > 10 A to 20 A - 1 min. operation max.
Resistance
DC Current
CC Current, Freq. Response: 40Hz-500Hz, sine wave spec. tested on 60Hz/50Hz
Multimeter