Microplater Reader / Food Analyzer
ELISA
UT-6500, Microplate Reader
UT-6500
Model
UT-6500
Absorbance range
0.000-4000 Abs
Resolution
0.001 Abs (display), 0.0001 Abs (calculated)
Wavelengths
340,405,450,492,630nm,3 more filters optional
Wavelength accuracy
±1nm
Band width
<8nm
Methodologies
End point, fixed time, Kinetic
Calculation method
ABS, cut-off, single standard, curve, multi-percent,
percent log, linear, exponential, power, 4PL regression
Reading speed
5 Seconds for 96 well plate (single wavelength)
Shaking plate
Shaking time and speed adjustable
Plate incubation
Ambient temperature +4~45
o
C, adjustable
Optic system
8-channel optic fiber system
Light source
Halogen lamp
Operation
PC operation, bidirectional communications
Memory
More than 500 programs, up to 100,000 test result
Printer
All printers compatible with windows
Interface
RS-232
Power requirement
AC 110V/240V ±10%, 50/60 ±1Hz
Net weight
9 kg
Dimensions (mm)
L186xW440xH220
Standard Filters:
405nm, 450nm, 492nm, 630nm.
Special Filters:
412nm, 420nm, 490nm, 505nm, 540nm, 550nm, 545nm,
546nm, 578nm, 595nm, 590nm, 570nm, 690nm, 650nm, 655nm, 600nm,
690nm, 530nm, 562nm, 620nm, 675nm, 685nm, 660nm.
Features:
UV wavelength available, including
340nm.
End Point, Fixed time, Kinetic.
Temperature control(optional),
incubation time & temp. adjustable.
PC controlled system, windows XP.
8-channel optical fiber system enables
5 secs' reading for the whole plate.
More than 500 Programs and minimum
100,000 results can be stored.
Powerful QC programs including
Westguard Multi-rule and Instant
method, automatic alarm.
Calculation modes include ABS,
cut-off, curve, linear, log. Exponential,
Power and 4PL regression.
Auto self- check when power on, with
lamp saving and plate shaking.
Random positive and negative control
setting.
Multl-assay enables up to 12 different
assays on one plate.
FSA-1510, Food Safety Analyzer
FSA-1510
Features:
Multiple tests on one analayzer,
includes Food Safely Analyze, Pesticide
Residues, Veterinary Drug Residues.
Antibiotic Residues, Determination of
Organic Pollutants, Natural Toxins. Safety
of Aquatic Products. Analysis of
Biological Pollutants etc.
Widely applied. not only in labs, but
also in On-site Screening, like Food and
Drug Administration ,Inspection and
Center for Disease Control and
Prevention, etc.
Multi-assay enables up to 96 tests and
12 different assays on one plate, 5 sec.
for 96 well plate (single wavelength). fast
and accurate.
Model
FSA-1510
Absorbance Range
0 - 4,500Abs
Resolution
0.001Abs(Displayed). 0.0001Abs (Calculated)
Accuracy
±0.1%or ±0.005Abs
Type of Microplate
Standard with96-wellor other kind of microplate &
strip
Wavelength
410, 450, 492, 630mm, 4 more filters optional
Wavelength Accuracy
±1nm
Band Width
8nm
Calculation Method
ABS, %ABS, Cut-Off, Single Standard, Curve, Multi-Precent,,
Precent Log, Linear, Exponential, Power, 4PL Regression
Reading Speed
5 seconds for 96 well plate (single wavelength)
Shaking Plate
Shaking time & speed adjustable
Memory
>100 programs, 100,000test results
Interface
RS-232, USB,SO card & LAN interface
Display
6” LCD, Touch panel
Power Supply
AC 110V - 220V ±10%, 50-60Hz
Net Weight
8kg
Dimensions (mm)
L460xW330xH190
Variety tests and calculation methods, meeting the requirements from
different areas of Food Safety
Easy Windows operation system with touch
screen Or mouse, large LCD display
22 pre programmed tests, covers area
in Pesticide Residues, Aquatic Pollution. Natural Toxins, Animal Diseases
Powerful QC function: Grubs, Westguard Multi-rule, Levey Jennings Plot
Professional software design, sample in two different tests, dilution ratio
adjustaable
Multiform result output including patient comprehensive report.