18
Electrolyte
Features:
●
Larger LCD with touch-screen(320x240)
●
Self-made maintenance free
electrodes
●
Sleep mode to save reagent
●
Rapid test speed. 25 seconds/test
●
Min-volume sample consumption: 60llL
●
Reagent pack to avoid pollution
●
On-line instructions provided for self
problem-solving
●
Protection function when powered-off
suddenly
●
Setting any time to power-off the
equipment, to save reagent when free
●
Randomly choose any combination of
pH, K, Na, CI, Ca, TC02, li, Ag channels.
Channel
Range
Resolution
CV%
pH
4.00 ~ 9.00
0.01
< 0.5
K
+
0.50 ~ 15.00 mmol/L
0.01
< 1.0
Na
+
30.0 ~ 200.0 mmol/L
0.1
< 1.0
Cl
‐
20.0 ~ 200.0 mmol/L
0.1
< 1.0
Ca
++
0.1 ~ 6.0 mmol/L
0.01
< 1.5
TCO2
+
2.0 ~ 70.0 mmol/L
0.1
< 3.0
Li
+
0.1 ~ 5.0 mmol/L
0.01
< 2.0
ELA-6000
ELA-6000, Electrolyte Analyzer
Sample type:
Plasma, Serum, Blood, Urine
Test range and accuracy:
Ambient Temperature
5°c ~ 35°c
Relative Humidity
≤
85%
Sun Radiation
Avoid direct sunshine
Power Supply
AC 220V±10V (50/60HZ)
Working environment:
Flow Path
Fluid Moving system
Reagent pack
Calibration solution in a single reagent pack
Calibration
Automatic or On
‐
demand
Memory Storage
Up to 1000 patient result, extended to be over
20000 results
Analyzing Time
25 seconds after aspiration
Sample Volume
60~300μL whole blood or serum
Input
Touch screen(with operation menu)
Output
Internal thermal
‐
printer ; RS232
Auto sampler
‐
35 samples volume (for optional function)
‐
39x31.5x36cm, N.W: 6.5kg
Waste Storage
Closed Pack System
Reagent Pack
Closed Reagent System
Dimensions
42x37x56 cm
Net weight
16 kg
Main characters:
Features:
●
Self-made maintenance free
electrodes
●
Sleep mode to save reagent
●
Rapid test speed. 30 seconds/test
●
Min-volume sample consumption: 651lL
●
Reagent pack to avoid pollution
●
On-line instructions provided for self
problem-solving
●
High efficient cleaning procedures,
best for fatty samples
●
High, middle and low QC values
provided to adjust linearity
●
Randomly choose any combination of
pH, K, Na, CI, Ca, Li channels
●
Automatic one point & two points
calibration with additional manual
calibration.
Channel
Range
Resolution
CV%
pH
6.00 ~ 9.00
0.01
< 1.0
K
+
0.50 ~ 10.00 mmol/L
0.01
< 1.0
Na
+
20.0 ~ 200.0 mmol/L
0.1
< 1.0
Cl
‐
20.0 ~ 200.0 mmol/L
0.1
< 1.0
Ca
++
0.3 ~ 5.0 mmol/L
0.01
< 1.5
Li
+
0.1 ~ 3.0 mmol/L
0.01
< 1.5
ELA-5100
ELA-5100, Electrolyte Analyzer
Sample type:
Plasma, Serum, Blood, Urine
Test range and accuracy:
Ambient Temperature
5°c ~ 40°c
Relative Humidity
≤
85%
Sun Radiation
Avoid direct sunshine
Power Supply
AC100
‐
240V(50/60HZ)
Working environment:
Flow Path
Fluid Moving system
Reagent pack
Calibration solution in a single reagent pack
Calibration
Automatic or On
‐
demand
Memory Storage
Up to 1500 patient result, 199 normal QC,
199 Abnormal QC
Analyzing Time
30 seconds after aspiration
Sample Volume
Minimum 65μL whole blood or serum
Display
Wide LCD (240x128)
Input
Keypad (16 alphabet Numeric display, YES or NO)
Output
Internal thermal
‐
printer ; RS232
Waste Storage
Closed Pack System
Reagent Pack
Closed Reagent System
Dimensions
30x26x36 cm
Net weight
7.5 kg
Main characters:
MEDICAL ANALYZERS
A