MRC-2013-Catalog - page 8

8
ANALYZERS
A
Milk
MIA-SLP
MIA-SLP/MIA-SLP-A, Economy Milk Analyzers
MIA-SLP 30sec:
Standard 30sec.
MIA-SLP 60sec:
Standard 60sec.
MIA-SLP-A 30sec:
Automatic 30sec.
MIA-SLP-A 60sec:
Automatic 60sec.
MIA-SLP/ MIA-SLP-A Options & Accessories:
MIA-EP: External Printer.
MIA-HF: Measuring high fat samples (cream) up to 45% (High Density).
MIA-DCP: Milk Data Collection Program.
MIA-PH: pH measurement - function.
MIA-CON: Conductivity measurement function.
MIA-P: pH probe.
MIA-EK: External keypad.
MIA-USB: USB.
MIA-RTC: Real time clock.
Consumables:
MIA-B7: Buffer solution Ph 50 ml (pH7.00±0.01/20°C).
MIA-B4: Buffer solution pH 50 ml (pH4.00±0.01/20°C).
MIA-B5ms: Buffer solution conductivity 50 ml (5.02 (±5%) mS/cm (18±0.1°C).
MIA-ALC: Alkaline cleaning powder.
MIA-ACC: Acidic cleaning powder.
MIA-PAPER: Printer paper roll.
Model
MIA-SLP/MIA-SLP-A
Measuring time
Measuring parameters
Standard complete
Additional options
60 Sec
FAT – 0.01% - 25%
SNF – 3% - 15%
Density – 1015 –1040kg/m
3
Proteins – 2% - 7%
Lactose – 0.01% - 6%
Water content – 0% - 70%
Temp. of milk – 1°C– 40°C
Freezing point - -0.400–0.700°C
Salts – 0.4 – 1.5%
PH - 0 – 14 ±0,05% (option)
Conductivity - 3 – 14
[mS/cm]±0,05% (option)
Total solids - 0 –50%
±0,17(option)
1. Hoses-spare pipes-1/2pcs
2. Sample holders-plastic
mugs–2 pcs
3. Switching adapter:
input: 100-240 V~1.6A
max. 50-60Hz
4. output: +12V 4.17A min.
5. Output power: 50-65W
6. Operation Manual
7. Standard Calibrations:
Cow-Sheep-UHT
8. Cardboard Box
9. CD – Service pack
Ph option
0-14
30 Sec
Conductivity
3-14ms/cm
Total Solids
0-50%
MIA-S
Model
MIA-S/MIA-SA
Measuring
time Measuring parameters
Standard complete Additional
options
90 Sec
FAT – 0.01% - 25%
SNF – 3% - 15%
Density – 1015 –1040kg/m
3
Proteins – 2% - 7%
Lactose – 0.01% - 6%
Water content – 0% - 70%
Temp. of milk – 1°C– 40°C
Freezing point -0.400 –0.700°C
Salts – 0.4 – 1.5%
PH - 0 – 14 ±0,05% (option)
Conductivity - 3 – 14
[mS/cm]±0,05% (option)
Total solids - 0 –25%
±0,17(option)
1. Hoses-spare pipes-2pcs
2. Sample holders-plastic
mugs–2 pcs
3. Switching adapter:
input: 100-240 V~1.6A
max. 50-60Hz
4. output: +12V 4.17A min.
5. Output power: 50-65W
6. Operation Manual
7. Standard Calibrations:
Cow-Sheep-UHT
8. Cardboard Box
9. CD – Service pack
Ph option
0-14
50 Sec
for SA
60 Sec
for S
Conductivity
3-14ms/cm
30 Sec
for S
Total Solids
0-25%
MIA-S/MIA-SA, Standard Milk Analyzers
MIA-S:
Standard.
MIA-SA:
Standard Automatic.
1,2,3,4,5,6,7 9,10,11,12,13,14,15,16,17,18,...738