13
Semi-Auto Chemistry
Model
SACA-19600
Principle
Absorbance
Absorbance Range
-0.500 ~ 3.500Abs
Resolution
0.001 Abs (displayed), 0.0001Abs (calculated)
Light Source
Halogen lamp
Wavelengths
Continuously adjusted grating, wavelength range is
330 - 800nm, 1nm by step adjustment
Wavelength Accuracy
± 1nm
Band Width
< 6nm
Flow cell
Metal - quartz flow cell
Temperature Control
25°C,30°C,37°C,±0.1°C and ambient temperature
Carryover
< 1%
Memory
200 test protocols, up to 10000 test results, support SD
to expand memory
Display
6.4" color/mono LCD
Interface
RS-232, support VGA,2 USB, SD, Ethernet
Output
Built-in printer, or external printer (optional)
Input
Touch screen, USB mouse and keyboard optional
Power Supply
AC 100V - 240V ± 10%,50-60Hz
Net Weight
11KG
Dimensions (mm)
L370xW284xH318
SACA-19600
Features:
●
Easy Windows operation system with
large touch-screen.
●
Displays the reaction curve in real-time.
SACA-19600, Semi-Auto Chemistry, Grating Inside, Touch Screen And USB
●
Continuously adjustable grating, enhances the stability and reliability of result
●
Reagent-open system supports flow
cell and cuvette mode, close system on request
●
Analytical modes include kinetic, fixed time, bichromatic end point
with or without reagent blank or sample blank, linear or non-linear calibration
●
Powerful QC program: Westguard
multi-rule, Levey-Jennings plots, 2 controls per test
●
Large memory, up to 200 test protocols and 10000 results can be
stored, compatible with SD card
●
Multiform result output including patient comprehensive report
●
Multi-interface
support RS-232, VGA, USB, SD and Ethernet
●
Easy communication with PC
●
Powerful internet connection enables
remote data sharing and OS update
●
Compact design enables USER-DIY maintenance
●
Multi-language software
available on request.
Features:
●
Easy keypad operation with LCD
display
●
Continuously adjustable grating,
enhances the stability and reliability of
result.
●
Reagent open system supports flow
Model
SACA-19900
Principle
Absorbance
Absorbance Range
-0.500 ~ 3.500Abs
Resolution
0.001 Abs (displayed), 0.0001Abs (calculated)
Light Source
Halogen lamp
Wavelengths
Continuously adjusted grating, wavelength range is
330 - 800nm, 1nm by step adjustment
Wavelength Accuracy
± 1nm
Band Width
< 6nm
Flow cell
Metal - quartz flow cell
Temperature Control
25°C,30°C,37°C,±0.1°C and ambient temperature
Aspirate Volume
0~3000µl
Carryover
< 1%
Memory
Up to 204 protocols and 5400 results can be stored
Display
LCD display
Interface
RS-232
Output
Built-in printer, or external printer (optional)
Power Supply
AC 110V - 220V ± 10%, 50-60Hz
Net Weight
8KG
Dimensions (mm)
L360xW318xH185
SACA-19900, Semi-Auto Chemistry, Grating Inside, Easy Keypad Operation With LCD Display
cell and cuvette mode, close system on request
●
Analytical modes include kinetic, fixed time, bichromatic end point
with or without reagent blank or sample blank, linear or non-linear calibration curves
●
Powerful QC program:
Westguard multi-rule, Levey-Jennings plots,2 controls per test
●
Large memory, up to 204 protocols and 5400 results
can be stored
●
Additional recloser design with lamp saving
●
Powerful internet connection enables remote data
sharing & OS update
●
Compact design enables USER-DIY maintenance
●
Multi-language software available on
request.