23
AUTOCLAVES
Vertical
●
Microcomputer control technique. touch-key. LCD display the menu.
●
Automatic control over the processes of filling water, heating, sterilization,
steam exhaust and dryness.
●
There are equipped with dressing, instrument, rubber, culture medium
sterilization and keep warm. culture medium and keep warm
programs for customer’s choice.
●
Process, temperature, time dynamic LCD displayed, Fault automatic
displayed and alarm.
●
Positive pressure pulse function exhaust cool air of chamber thoroughly
and ensure the steam saturation.
●
Rapid and slow exhaust steam Automatic control function, It avoids liquid
overflow while sterilization.
●
Automatic maintenance function, The program will he continued when
the power connection again.
●
The buzzer alarms when a cycle of operation is completed.
●
Preheating control function.
●
Built-in water tank. Steam and water circulation system.
no external water source. not exhaust steam outside.
environment is clean and dryness.
●
Horizontal sliding door,
self- bulge seal ring.
operated easily.
●
Printer is available
for optional.
Model
Capacity
Chamber Size
Outside Size (mm)
Net weight
Voltage
Power
STE-V-60
50L
Ø
315xL668mm
616x476x990
65kg
220V/50Hz
4.2Kw
STE-V-80
80L
Ø
386xL695mm
688x546x1030
75kg
380V/50Hz
4.5Kw
Safety Devices
●
Auto protection device against over
temperature: This system cuts off
power automatically if the designed
temperature is surpassed. Light and
sound alarm meanwhile.
STE-V-80
STE-V-60/80, Automated Water Filling Vertical Autoclave
Baskets
SK310-230/SK410-230, Heat Sealer, sealing width - 300/400mm
●
It fits nearly everywhere for world-wide use in laboratory.
●
Polyethylene, polypropylene films can be easily sealed.
●
Easy to handle with convenient and reasonable structure.
●
Powerful transformer and high quality circuit components guarantee years
operation.
SK310-230
Model
SK310-230
SK410-230
Available resin
polyethylene, polypropylene
Sealing width
2mm
Sealing length
300mm
400mm
Weight
4.3kg
5.4kg
Dimensions (mm)
W440xD85xH175
W530xD85xH175
Wattage
390W
750W
Power
AC 110V/220V, 50/60Hz
Main Technical Parameters
●
Designed pressure: 0.26Mpa.
●
Designed temperature: 150°C.
●
Rated working pressure: 0.22Mpa.
●
Sterilization temperature: 105°C-136°C.
●
Sterilization time range: 0-99min.
●
Material of chamber: SUS 304 stainless
steel.
●
Accessories: 2 stainless steel sterilization
baskets.
A
STE-V-80
●
The program will he stopped if water level lower than the low limit. alarm with sound and light.
●
Door safety interlock. The door cannot be opened until there is no pressure in the chamber and power for heating
cannot be switched on until the door is firmly closed.
●
Safety valve of auto release against overpressure It opens when the designed pressure is surpassed.
●
Heat insulation dock shelter: the door is made of high performance heat insulation material. not only beautiful but
also prevents the operator 10 be injured.
●
Over current and creepage protector.
updated Mar2014