Coagulation
Model
CA-02C
Analysis Parameters
PT, APTT, TT, FIB, F2, F5, F7, F8, F9, F10, F11, F12, Heparin,
APC-R, Protein S, Protein C
Principle
Scattered light with percentage analysis
Sample Volume
Required
PT: 25µl, APTT: 25µl, TT: 25µl, FIB: 25µl
Testing Channel
2 Channels
Light Source
Durable LED detector
Sample Position
5 positions
Reagent Position
2 positions (1 magnetic mixer included)
Testing Time
Normally 20~60 secs, Maximum time up to 600 secs
Minimum Reagent
Consumption
30µL for APTT, 50µL for FIB, PT, APTT
Position Warming-up
37°C(±0.5°C)
Memory
6,000 test results
Display
LCD display
Interface
RS-232
Input
Easy operation keypad
Output
Internal printer
Power supply
AC 110-220V±10%, 50~60Hz
Net Weight
5KG
Dimension (mm)
L270xW270xH120
CA-02C, 2-Channel Coagulometer With Internal Printer
Features:
2 channel (2 durable LED detectors
for 2 different parameters analysis)
Easy keypad operation with LCD
display
Internal thermal-sensitive printer;
Electronically-linked Pipette
optional
Reagent position with magnetic
rotor.
Scattered light and percentage
analysis ensure good results.
Open reagent system with low
CA-02C
consumption, close reagent on request
Large memory to store up to 6000 test results
QC and calibration
program incorporated
Auto self-check when power on
Multi-language software available on request.
Model
CA-01C
Analysis Parameters
PT, APTT, TT, FIB, F2, F5, F7, F8, F9, F10, F11, F12, Heparin,
APC-R, Protein S, Protein C
Principle
Scattered light with percentage analysis
Sample Volume
Required
PT: 25ul, APTT: 25ul, TT: 25ul, FIB: 25ul
Testing Channel
1 Channels
Light Source
Durable LED detector
Sample Position
5 positions
Reagent Position
2 positions (1 magnetic mixer included)
Testing Time
Normally 20~60 secs, Maximum time up to 600 secs
Minimum Reagent
Consumption
30µL for APTT, 50µL for FIB, PT, APTT
Position Warming-up
37°C(±0.5°C)
Memory
6,000 test results
Display
LCD display
Interface
RS-232
Input
Easy operation keypad
Output
Internal printer
Power supply
AC 110-220V±10%, 50~60Hz
Net Weight
5KG
Dimension (mm)
L270xW270xH120
CA-01C
CA-01C, 1-Channel Coagulometer With Internal Printer
Features:
1 channel (LED detector).
Easy keypad operation with LCD
display.
Internal thermal-sensitive printer;
Electronically-linked Pipette optional.
Reagent position with magnetic rotor.
Scattered light and percentage
analysis ensure good results
Open reagent system with low
consumption, close reagent on request.
Large memory to store up to 6000 test
results.
QC & calibration program incorporated.
Auto self-check when power on.
MEDICAL ANALYZERS