Instrumentation Valves014 - page 96

actuatorsandaccessories
196
|
VICIAG International Sales: +41–41–925–6200 Fax: +41–41–925–6201
|
DigitalValveSequenceProgrammer (DVSP)
more information
Actuators
Air . . . .pages194-195
Microelectric . . 188-191
Standardelec . . . . 193
Controllersand
Interfaces
HSSA . . . . . . . . 198
High speed
switchingaccessory
PFAF . . . . . . . . .199
Position feedback
for air actuators
PFW/PFC . . . . . . 199
Position feedback
formanual valves
MountingHardware
Closemount
hardware . . page208
Right angledrive . . .204
Standoff assembly . .205
Standoffmounting
e . . . . . 205
Thedigital valve sequence
programmer (DVSP) isanadd-on
or stand-alone timer/programmer
with4 intervals,settable in rangesof
0-99 seconds,0-9.9minutes,or 0-99
minutes. TheDVSP ismost commonly
used for remoteoperationof electrical
devices suchas solenoidvalves,Valco
twopositionormultipositionelectric
actuators,and theValcoDVI (digital
valve interface),whichconverts
contact closures intopneumaticpulses
for switchingValco twopositionair
actuators.
TheDVSPhas twooperational
modes: in theAUTOmode, theDVSP
will return to thefirst interval and
beginanother sequenceafter the
last interval is completed,and in the
SINGLECYCLEmode it stopsafter
completingone sequence. During
acycleor sequence,simplecontrols
allow theuser to stop thecycle, reset it
to Interval 1,switch to theAUTOmode,
or advance to thenext interval. The
DVSPcanalsobewired for remote
operationbycontact closure froma
data systemorother control device.
Each interval hasonedoublepole,
double throw relay, ratedat 5amps,
whichprovides two setsof contacts
withnoconnection fromone side to
theother. Thismeans that a single
interval canbeused toperform two
separate functions requiringdiffering
voltage requirements. For example,
one sideof RelayA (Interval 1) canbe
used to switchanelectricactuator
(contact closure)while theother
side is connected to110/230VAC
and switchesa110/230VAC solenoid
valveat the same timeas theelectric
actuator. Inaddition,RelayE supplies
a two secondcontact. When solenoid
valvesarewired in serieswith this
relay the result is“pulsedoperation”
of theair actuator,whichavoids the
potential valveandactuatorproblems
associatedwithcontinuously-applied
airpressure.
Both12VDCand110/230VACpower
suppliesare includedwithin theDVSP,
but the relaysmaybe suppliedwith
power fromanexternal power source.
For example,24VDC solenoidvalves
canbe switchedby theDVSP relays if
the24volts is supplied to the relays
fromanexternal 24VDCpower supply.
DVSP
forallairand
Digital valvesequenceprogrammer
electricactuators
ProdNo
110VAC
DVSP4
230VAC
DVSP4-220
CHROMalyticTECHnologyPtyLtdAUSTRALIANDistributors e-mail: