fastfacts07 - page 70

ID
0.25mm
Length
5m
10m
Suffix #*
-124
-127
Gas Chromatography Columns&Accessories
For these items, seeRestek’s
Chromatography Products Catalog:
• Syringes
• AutosamplerVials
• GuardColumns
• Ferrules, Septa
Recommended Gas Chromatography Columns
Rtx
®
-5, 30m x 0.25mm
Film Thickness
temp. limits
Cat. #
0.25µm
-60 to 330/350°C
10223
0.50µm
-60 to 330/350°C
10238
1.00µm
-60 to 320/340°C
10253
Integra-Guard
Columns
Guard and analytical column in one connectionless length.
*Add the appropriate suffix number to analytical column catalog number.
Syringes
StandardMicro-Liter Syringes for Agilent 7673 and 7683 Autosamplers
Size
Needle Gauge
6-pk.
10µL
23s
20169
10µL
23s–26s
24600
Autosampler Vials
Crimp Top Vial Snap Seal
Style (12 x 32mm, 11mmCrimp)
Description*
1,000-pk.
2.0mLClear Glass Vial w/White GraduatedMarking Spot
24384
2.0mL Amber Glass Vial w/White GraduatedMarking Spot
24386
*Marking spots are available on request in blue, green, rust or yellow.
AluminumCrimp Sealsw/Septa
Description
1,000-pk.
Silver Seal, PTFE/Natural Rubber Septa
21175
Silver Seal, PTFE/Silicone Septa*
24360
*PTFE/Silicone/PTFE available on request.
Thermolite
®
Septa
Size
temp. limits
25-pk.
50-pk.
100-pk.
11mm (
7
/
16
”)
to 340°C
20363
20364
20365
Replacement Inlet Seals
Stainless Steel Inlet Seal for Single-Column Installation*
Size
2-pk.
10-pk.
0.8mm ID
21315
21316
*Equivalent toAgilent Part# 18740-20880.
Inlet Liners
For Agilent GCs
Description
ID /OD& Length (mm)
ea.
5-pk.
Uniliner
®
*
4.0 ID, 6.3OD x 78.5
20335
20336
DrilledUniliner
®
4.0 ID, 6.3OD x 78.5
21054
21055
1mmSplit**
1.0 ID, 6.3OD x 78.5
20972
20973
*Restek design improves performance over the original Agilent Liner.
**Use this liner for increased sensitivity.
LowVolume Injector for Agilent GCs
Description
kit.
Low-Volume Injector for Agilent Split/Splitless GC Inlets
21692
Analytical ReferenceMaterials:
MAVPH (Jan. 1998)
Tomeasure thecollectiveconcentrationsof volatilealiphaticand
aromatic petroleumhydrocarbons inwater and soil. Themethod
isbasedonapurgeand trap, gas chromatographyprocedurewith
PID/FID in series for detection.
CalibrationMixtures
Massachusetts
n
-pentane (C5)
1,000µg/mL
n
-nonane (C9)
1,000
benzene
500
2,5-dibromotoluene (surrogate) 1,000
ethylbenzene
500
isooctane
1,500
2-methylpentane
1,500
methyl
tert
-butyl ether
1,500
naphthalene
1,000
toluene
1,500
1,2,4-trimethylbenzene
1,000
m
-xylene
1,000
o
-xylene
1,000
p
-xylene
1,000
InP&Tmethanol, 1mL/ampul
MAVPH Standardwith Surrogate
Each
5-pk.
10-pk.
30452
30452-510
w/data pack
30452-500
30452-520
30552
n
-pentane (C5)
1,000µg/mL
n
-nonane (C9)
1,000
benzene
500
ethylbenzene
500
isooctane
1,500
2-methylpentane
1,500
methyl
tert
-butyl ether
1,500
naphthalene
1,000
toluene
1,500
1,2,4-trimethylbenzene
1,000
m
-xylene
1,000
o
-xylene
1,000
p
-xylene
1,000
InP&Tmethanol, 1mL/ampul
MAVolatilePetroleum
Hydrocarbon (VPH) Standard
Each
5-pk.
10-pk.
30434
30434-510
w/data pack
30434-500
30434-520
30534
2,5-dibromotoluene
1,000µg/mL inP&Tmethanol, 1mL/ampul
MAVPH Surrogate Standard
Each
5-pk.
10-pk.
30435
30435-510
w/data pack
30435-500
30435-520
30535
10,000µg/mL inP&Tmethanol, 1mL/ampul
Each
5-pk.
10-pk.
30453
30453-510
w/data pack
30453-500
30453-520
30553
n
-pentane (C5)
n
-nonane (C9)
benzene
2,5-dibromotoluene
(surrogate)
ethylbenzene
isooctane
2-methylpentane
methyl
tert
-butyl ether
naphthalene
toluene
1,2,4-trimethylbenzene
m
-xylene
o
-xylene
p
-xylene
2,500µg/mL each inP&Tmethanol, 1mL/ampul
MAVPHMatrix SpikeMixwith Surrogate
Each
5-pk.
10-pk.
30454
30454-510
w/data pack
30454-500
30454-520
30554
SurrogateMixtures
Matrix SpikeMixtures
1...,60,61,62,63,64,65,66,67,68,69 71,72,73,74,75,76,77,78,79,80,...152
Powered by FlippingBook