fastfacts07 - page 76

ID
0.25mm
Length
5m
10m
Suffix #*
-124
-127
Each
5-pk.
10-pk.
30067
30067-510
w/data pack
30067-500
30067-520
30167
Gas Chromatography Columns&Accessories
For these items, seeRestek’s
Chromatography Products Catalog:
• Syringes
• AutosamplerVials
• GuardColumns
• Ferrules, Septa
Recommended Gas Chromatography Columns
Rtx
®
-5, 30m x 0.25mm
Film Thickness
temp. limits
Cat. #
0.25µm
-60 to 330/350°C
10223
0.50µm
-60 to 330/350°C
10238
1.00µm
-60 to 320/340°C
10253
Integra-Guard Columns
Guard and analytical column in one connectionless length.
*Add the appropriate suffix number to analytical column catalog number.
Syringes
StandardMicro-Liter Syringes for Agilent 7673 and 7683 Autosamplers
Size
Needle Gauge
6-pk.
10µL
23s
20169
10µL
23s–26s
24600
Autosampler Vials
Crimp Top Vial Snap Seal
Style (12 x 32mm, 11mmCrimp)
Description*
1,000-pk.
2.0mLClear Glass Vial w/White GraduatedMarking Spot
24384
2.0mL Amber Glass Vial w/White GraduatedMarking Spot
24386
*Marking spots are available on request in blue, green, rust or yellow.
AluminumCrimp Sealsw/Septa
Description
1,000-pk.
Silver Seal, PTFE/Natural Rubber Septa
21175
Silver Seal, PTFE/Silicone Septa*
24360
*PTFE/Silicone/PTFE available on request.
Thermolite
®
Septa
Size
temp. limits
25-pk.
50-pk.
100-pk.
11mm (
7
/
16
”)
to 340°C
20363
20364
20365
Replacement Inlet Seals
Stainless Steel Inlet Seal for Single-Column Installation*
Size
2-pk.
10-pk.
0.8mm ID
21315
21316
*Equivalent toAgilent Part# 18740-20880.
Inlet Liners
For Agilent GCs
Description
ID /OD& Length (mm)
ea.
5-pk.
Uniliner
®
*
4.0 ID, 6.3OD x 78.5
20335
20336
DrilledUniliner
®
4.0 ID, 6.3OD x 78.5
21054
21055
1mmSplit**
1.0 ID, 6.3OD x 78.5
20972
20973
*Restek design improves performance over the original Agilent Liner.
**Use this liner for increased sensitivity.
LowVolume Injector for Agilent GCs
Description
kit.
Low-Volume Injector for Agilent Split/Splitless GC Inlets
21692
Analytical ReferenceMaterials:
WI GRO (Sept. 1995)
The method is designed to measure concentrations of gasoline
range organics (GRO) (C6-C10) in water or soil. Petroleum
volatile organic compounds (PVOCs) canbe determined concur-
rentlyby thismethod. It is basedonpurge and trap,GC/FIDpro-
cedure. FID/PID in series is used forGRO/PVOCs concurrently.
benzene
ethylbenzene
methyl
tert
-butyl ether
naphthalene
toluene
1,2,4-trimethylbenzene
1,3,5-trimethylbenzene
m
-xylene
o
-xylene
p
-xylene
1,000µg/mL each inP&Tmethanol, 1mL/ampul
PVOC/GROMix (Wisconsin)
Each
5-pk.
10-pk.
30095
30095-510
w/data pack
30095-500
30095-520
30195
4-bromofluorobenzene
10,000µg/mL inP&Tmethanol, 1mL/ampul
Each
5-pk.
10-pk.
30082
30082-510
w/data pack
30082-500
30082-520
30182
2,500µg/mL inP&Tmethanol, 1mL/ampul
α
,
α
,
α
-trifluorotoluene
Each
5-pk.
10-pk.
30068
30068-510
w/data pack
30068-500
30068-520
30168
10,000µg/mL inP&Tmethanol, 1mL/ampul
Each
5-pk.
10-pk.
30083
30083-510
w/data pack
30083-500
30083-520
30183
2,000µg/mL inP&Tmethanol, 1mL/ampul
fluorobenzene
Each
5-pk.
10-pk.
30030
30030-510
w/data pack
30030-500
30030-520
30130
2,500µg/mL inP&Tmethanol, 1mL/ampul
CalibrationMixtures
SurrogateMixtures
Wisconsin
1...,66,67,68,69,70,71,72,73,74,75 77,78,79,80,81,82,83,84,85,86,...152