fastfacts07 - page 82

ID
0.25mm
Length
5m
10m
Suffix #*
-124
-127
w/data pack
Each
31483
31483-500
5-pk.
31483-510
31483-520
10-pk.
31583
each in pentane, 1mL/ampul
Each
5-pk.
10-pk.
31484
31484-510
w/data pack
31484-500
31484-520
31584
Each
5-pk.
10-pk.
31482
31482-510
w/data pack
31482-500
31482-520
31582
TX TPHCalibrationMix
diesel fuel #2 composite
unleaded gasoline composite
TX TPHMatrix SpikeMix
diesel fuel #2 composite
unleaded gasoline composite
10,000µg/mL each inP&Tmethanol, 1mL/ampul
AlternateBoilingPoint/CarbonNumber
DistributionMarker Stock Standard
hexane (C6)
octane (C8)
decane (C10)
dodecane (C12)
hexadecane (C16)
heneicosane (C21)
octacosane (C28)
pentatriacontane (C35)
hexatriacontane (C36)
200µg/mL each in pentane, 1mL/ampul
TX TPH LocatorMix
hexane (C6)
decane (C10)
octacosane (C28)
200µg/mL each in pentane, 1mL/ampul
Gas Chromatography Columns&Accessories
For the below items, seeRestek’s
Chromatography Products Catalog
• Syringes
• AutosamplerVials
• GuardColumns
• Ferrules, Septa
Recommended Gas Chromatography Columns
Rtx
®
-5, 30m x 0.25mm
Film Thickness
temp. limits
Cat. #
0.25µm
-60 to 330/350°C
10223
0.50µm
-60 to 330/350°C
10238
1.00µm
-60 to 320/340°C
10253
Integra-Guard
Columns
*Add the appropriate suffix number to analytical column catalog number.
Syringes
StandardMicro-Liter Syringes for Agilent 7673 and 7683 Autosamplers
Size
Needle Gauge
6-pk.
10µL
23s
20169
10µL
23s–26s
24600
Autosampler Vial
Crimp Top Vial Snap Seal
Style (12 x 32mm, 11mmCrimp)
Description*
1,000-pk.
2.0mLClear Glass Vial w/White GraduatedMarking Spot
24384
2.0mL Amber Glass Vial w/White GraduatedMarking Spot
24386
*Marking spots are available on request in blue, green, rust or yellow.
AluminumCrimp Sealsw/Septa
Description
1,000-pk.
Silver Seal, PTFE/Natural Rubber Septa
21175
Silver Seal, PTFE/Silicone Septa*
24360
*PTFE/Silicone/PTFE available on request.
Thermolite
®
Septa
Size
temp. limits
25-pk.
50-pk.
100-pk.
11mm (
7
/
16
”)
to 340°C
20363
20364
20365
Replacement Inlet Seals
Stainless Steel Inlet Seal for Single-Column Installation*
Size
2-pk.
10-pk.
0.8mm ID
21315
21316
*Our stainless steel inlet seal is equivalent toAgilent Part# 18740-20880.
Inlet Liners
For Agilent GCs
Description
ID /OD& Length (mm)
ea.
5-pk.
Uniliner
®
*
4.0 ID, 6.3OD x 78.5
20335
20336
DrilledUniliner
®
4.0 ID, 6.3OD x 78.5
21054
21055
1mmSplit**
1.0 ID, 6.3OD x 78.5
20972
20973
*Restek design changes improve performance over the original Agilent Liner.
**Use this liner for increased sensitivity.
LowVolume Injector for Agilent GCs
Description
kit
Low-Volume Injector for Agilent Split/Splitless GC Inlets
21692
Retention TimeCalibrationMixtures
Matrix SpikeMixtures
Analytical ReferenceMaterials
CalibrationMixtures
Note:
Restek includes bothC35andC36as themethodallows the laboratory
touseC36, if the laboratory is unable to locate theC35 reference standard
(TNRCC 1005& 1006, paragraph 2.0).
TNRCCMethod 1005,
Revision 3, (6-1-2001)
Todetermine the total concentrations of petroleumhydrocarbons
(TPH) (C6-C35) in solid and aqueous matrices. It is based on
solvent/solid extraction andGC/FID.
w/data pack
Each
31639
31639-500
5-pk.
31639-510
31639-520
10-pk.
31739
1...,72,73,74,75,76,77,78,79,80,81 83,84,85,86,87,88,89,90,91,92,...152