ID
0.25mm
Length
5m
10m
Suffix #*
-124
-127
Gas Chromatography Columns&Accessories
For these items, seeRestek’s
Chromatography Products Catalog:
• Syringes
• AutosamplerVials
• GuardColumns
• Ferrules, Septa
Recommended Gas Chromatography Columns
Rtx
®
-5, 30m x 0.25mm
Film Thickness
temp. limits
Cat. #
0.25µm
-60 to 330/350°C
10223
0.50µm
-60 to 330/350°C
10238
1.00µm
-60 to 320/340°C
10253
Integra-Guard
Columns
Guard and analytical column in one connectionless length.
*Add the appropriate suffix number to analytical column catalog number.
Syringes
StandardMicro-Liter Syringes for Agilent 7673 and 7683 Autosamplers
Size
Needle Gauge
6-pk.
10µL
23s
20169
10µL
23s–26s
24600
Autosampler Vials
Crimp Top Vial Snap Seal
Style (12 x 32mm, 11mmCrimp)
Description*
1,000-pk.
2.0mLClear Glass Vial w/White GraduatedMarking Spot
24384
2.0mL Amber Glass Vial w/White GraduatedMarking Spot
24386
*Marking spots are available on request in blue, green, rust or yellow.
AluminumCrimp Sealsw/Septa
Description
1,000-pk.
Silver Seal, PTFE/Natural Rubber Septa
21175
Silver Seal, PTFE/Silicone Septa*
24360
*PTFE/Silicone/PTFE available on request.
Thermolite
®
Septa
Size
temp. limits
25-pk.
50-pk.
100-pk.
11mm (
7
/
16
”)
to 340°C
20363
20364
20365
Replacement Inlet Seals
Stainless Steel Inlet Seal for Single-Column Installation*
Size
2-pk.
10-pk.
0.8mm ID
21315
21316
*Equivalent toAgilent Part# 18740-20880.
Inlet Liners
For Agilent GCs
Description
ID /OD& Length (mm)
ea.
5-pk.
Uniliner
®
*
4.0 ID, 6.3OD x 78.5
20335
20336
DrilledUniliner
®
4.0 ID, 6.3OD x 78.5
21054
21055
1mmSplit**
1.0 ID, 6.3OD x 78.5
20972
20973
*Restek design improves performance over the original Agilent Liner.
**Use this liner for increased sensitivity.
LowVolume Injector for Agilent GCs
Description
kit.
Low-Volume Injector for Agilent Split/Splitless GC Inlets
21692
Florida
Analytical ReferenceMaterials:
FL-PRO, Revision 1 (11-1-1995)
Recommended Surrogate
nonatriacontane (C39), 3000 µg/mL in carbon disulfide,
working solution 300µg/mL in acetone.
n
-nonatriacontane (C39)
3,000µg/mL in carbon disulfide, 1mL/ampul*
Florida TRPH SurrogateMix
*Ground transportation shipments only.
Each
5-pk.
10-pk.
31456
31456-510
w/data pack
31456-500
31456-520
31556
n
-octane (C8)
n
-decane (C10)
n
-dodecane (C12)
n
-tetradecane (C14)
n
-hexadecane (C16)
n
-octadecane (C18)
n
-eicosane (C20)
n
-docosane (C22)
n
-tetracosane (C24)
n
-hexacosane (C26)
n
-octacosane (C28)
n
-triacontane (C30)
n
-dotriacontane (C32)
n
-tetratriacontane (C34)
n
-hexatriacontane (C36)
n
-octatriacontane (C38)
n
-tetracontane (C40)
500µg/mL each in hexane, 1mL/ampul
Florida TRPH Standard
Each
5-pk.
10-pk.
31266
31266-510
w/data pack
31266-500
31266-520
31366
10,000µg/mL inmethylene chloride, 1mL/ampul
o
-Terphenyl Standard
Each
5-pk.
10-pk.
31097
31097-510
w/data pack
31097-500
31097-520
31197
2,000µg/mL in acetone, 1mL/ampul
Each
5-pk.
10-pk.
31066
31066-510
w/data pack
31066-500
31066-520
31166
Pattern Recognition Standards (Optional)
Used to identify petroleum product type.
PetroleumHydrocarbon Standard
2,500µg/mL inP&Tmethanol, 1mL/ampul
UnleadedGasolineComposite Standard
Each
5-pk.
10-pk.
30081
30081-510
w/data pack
30081-500
30081-520
30181
50,000µg/mL inP&Tmethanol, 1mL/ampul
Each
5-pk.
10-pk.
30205
30205-510
w/data pack
30205-500
30205-520
30305
50,000µg/mL inP&Tmethanol, 5mL/ampul
Each
5-pk.
10-pk.
30206
30206-510
w/data pack
30206-500
30206-520
30306
n
-hexane (C6)
n
-decane (C10)
n
-dodecane (C12)
1,000µg/mL each inP&Tmethanol, 1mL/ampul
Retention TimeMarker
Each
5-pk.
10-pk.
30483
30483-510
w/data pack
30483-500
30483-520
30583