fastfacts07 - page 61

Ethanol Analytical
Reference Standards for
Blood Alcohol Testing
At-a-Glance
Product
Information
fromRestek
800-356-1688
814-353-1300
acetaldehyde
acetone
acetonitrile
ethanol (NIST certified value)
ethyl acetate
isopropanol
methanol
methyl ethyl ketone
BloodAlcoholMix ResolutionControl Standard
(8 components)
Forensic Ethanol Solutionsw/data pack
0.100g/dL each inwater, 1mL/ampul
Eachw/data pack
36256
Legal limits for blood alcohol in the United States are set at either 0.080 or
0.100g/dL. We offer high- and low-concentration standards so that laboratories
can construct calibration curves that bracket either legal limit concentration. In
addition, we offer 0.015g/dL and 0.025g/dL concentrations, which are important
in “zero-tolerance” cases involvingminors or convictedDUI offenders.
These standards areNational Institute of Standards andTechnology (NIST)-trace-
able and are shipped with a complete data pack that includes a Certificate of
Analysis, copies of all rawmaterial testing results, statistical QA results, analyti-
cal balance printout, and a lot sheet showing gravimetricweight of each analyte.
Use our Resolution Control Standard mix to verify the retention time for each
compound normally detected in a blood alcohol test, and to verify that the com-
pounds are resolved from anddonot interferewith eachother. Each compound in
this resolutionmix is 0.100g/dL. The ethanol concentration is anNIST-traceable
certified value.
We also offer Rtx
®
-BAC1 and Rtx
®
-BAC2 columns, which can resolve a blood
alcohol sample in less than3minutes. If youhave anyquestions about blood alco-
hol methods, or these products, please contact our Technical Service Team at
or via phone at 800-356-1688 or 814-353-1300, ext. 4.
To order call ext. 3.
NIST-traceable ethanol calibration standards from 0.015g/dL to
0.4g/dL inwater.
Eight-component resolution control standardwithNIST-certified
ethanol concentration.
Datapack and Certificate of Analysis providedwith each standard.
Note:
Ethanol Standards
Expiration date for each solution is
36months from the date of manufacture.
CustomResolution
Control Standard
Expiration date is 18months from the
date of manufacture.
Capillary GCColumns
Rtx
®
-BAC1 (fused silica)
ID
df (µm)
30-Meter
0.32mm
1.80
18003
0.53mm
3.00
18001
Rtx
®
-BAC2 (fused silica)
ID
df (µm)
30-Meter
0.32mm
1.20
18002
0.53mm
2.00
18000
MXT
®
-BAC1 (Silcosteel
®
-treated stainless
ID
df (µm)
30-Meter
0.53mm
3.00
78001
MXT
®
-BAC2 (Silcosteel
®
-treated stainless
ID
df (µm)
30-Meter
0.53mm
2.00
78000
Forensic ethanol solutions
w/data pack
5-pk.
1mL/ampul
10-pk.
1mL/ampul
ea.
5mL/ampul
ea.
20mL/ampul
0.015g/dL forensic ethanol solution
36232
36332
36240
36248
0.02g/dL forensic ethanol solution
36233
36333
36241
36249
0.025g/dL forensic ethanol solution
36234
36334
36242
36250
0.04g/dL forensic ethanol solution
36235
36335
36243
36251
0.05g/dL forensic ethanol solution
36257
36259
36258
36260
0.08g/dL forensic ethanol solution
36262
36264
36263
36265
0.1g/dL forensic ethanol solution
36236
36336
36244
36252
0.15g/dL forensic ethanol solution
36237
36337
36245
36253
0.2g/dL forensic ethanol solution
36238
36338
36246
36254
0.3g/dL forensic ethanol solution
36239
36339
36247
36255
0.4g/dL forensic ethanol solution
36266
36268
36267
36269
1...,51,52,53,54,55,56,57,58,59,60 62,63,64,65,66,67,68,69,70,71,...152