fastfacts07 - page 60

Restek (U.S.):
110 Benner Circle
Bellefonte, PA 16823
800-356-1688
• 814-353-1300
fax: 814-353-1309
Restek France:
01-60-78-32-10
fax: 01 60 78 70 90
Restek GmbH:
(49) 06172-2797-0
fax: (49) 06172-2797-77
Restek Ireland:
44-28-9081-4576
fax: 44-28-9081-4576
Thames Restek U.K., Ltd.:
01494-563377
fax: 01494-564990
©Copyright 2003, RestekCorporation
At-a-Glance
Product
Information
fromRestek
Restek trademarks:
Pinnacle II, Trident, Restek logo.
Reference Standards for Explosives Analysis
Lit. Cat. # 59381A
Restek is your free
technical literature source!
ApplicationNote:
(#59177) Analyze Polar Compounds by Reversed
Phase HPLCUsingUltra Aqueous C18 Column
Fast Facts:
(#59314) Trident
Direct Guard
Cartridge System
For literature:
Call
814-353-1300 or
800-356-1688, ext. 5
Fax
814-353-1309
Online
2-amino-4,6-dinitrotoluene
4-amino-2,6-dinitrotoluene
1,3-dinitrobenzene
2,4-dinitrotoluene
2,6-dinitrotoluene
HMX
RDX
tetryl
1,3,5-trinitrobenzene
2,4,6-trinitrotoluene
1,3-dinitrobenzene
2,4-dinitrotoluene
HMX
nitrobenzene
RDX
1,3,5-trinitrobenzene
2,4,6-trinitrotoluene
2-amino-4,6-dinitrotoluene
4-amino-2,6-dinitrotoluene
2,6-dinitrotoluene
2-nitrotoluene
3-nitrotoluene
4-nitrotoluene
tetryl
1,000µg/mL each in acetonitrile, 1mL/ampul
8095CalibrationMix A
Method 8095
Method 8330
3,5-dinitroaniline
1,000µg/mL
nitrobenzene
5,000
nitroglycerine
5,000
2-nitrotoluene
5,000
3-nitrotoluene
5,000
4-nitrotoluene
5,000
PETN
5,000
Prepared in acetonitrile, 1mL/ampul
8095CalibrationMix B
Each
5-pk.
10-pk.
31608
31608-510
w/data pack
31608-500
31608-520
31708
2-amino-4,6-dinitrotoluene 200µg/mL
4-amino-2,6-dinitrotoluene 200
1,3-dinitrobenzene
200
2,4-dinitrotoluene
200
2,6-dinitrotoluene
200
HMX
2,000
RDX
200
tetryl
200
1,3,5-trinitrobenene
200
2,4,6-trinitrotoluene
200
Prepared in acetonitrile, 1mL/ampul
8095Matrix SpikeMix A
Each
5-pk.
10-pk.
31609
31609-510
w/data pack
31609-500
31609-520
31709
3,5-dinitroaniline
200µg/mL
nitrobenzene
1,000
nitroglycerine
1,000
2-nitrotoluene
1,000
3-nitrotoluene
1,000
4-nitrotoluene
1,000
PETN
1,000
31450: 8330CalibrationMix #1
31451: 8330CalibrationMix #2
31452: 8330 Internal StandardMix*
31453: 8330 SurrogateMix
Prepared in acetonitrile, 1mL/ampul
8095Matrix SpikeMix B
Each
5-pk.
10-pk.
31610
31610-510
w/data pack
31610-500
31610-520
31710
2-methyl-4-nitroaniline
1,000µg/mL inmethanol, 1mL/ampul
8095 Surrogate
Each
5-pk.
10-pk.
31612
31612-510
w/data pack
31612-500
31612-520
31712
3,4-dinitrotoluene
1,000µg/mL inmethanol, 1mL/ampul
1,2-dinitrobenzene
1,000µg/mL inmethanol, 1mL/ampul
8330 Internal Standard*
Each
5-pk.
10-pk.
31452
31452-510
w/data pack
31452-500
31452-520
31552
Each
5-pk.
10-pk.
31607
31607-510
w/data pack
31607-500
31607-520
31707
8330CalibrationMix #1
1,000µg/mL each in acetonitrile, 1mL/ampul
Each
5-pk.
10-pk.
31450
31450-510
w/data pack
31450-500
31450-520
31550
8330CalibrationMix #2
1,000µg/mL each in acetonitrile, 1mL/ampul
Each
5-pk.
10-pk.
31451
31451-510
w/data pack
31451-500
31451-520
31551
8330 Surrogate
Each
5-pk.
10-pk.
31453
31453-510
w/data pack
31453-500
31453-520
31553
8330Nitroaromatics Kit
Contains 1mL each of thesemixtures.
* Cat.# 31452 also can be used as a surrogate
standard forMethod 8095.
Kit
Kit w/Data Pack
31454
31454-500
Rtx
®
-TNT/Rtx
®
-TNT2
Capillary GCColumns
Better resolution of Method 8095
analytes, in 20minutes
Eight elution order differences
Rtx
®
-TNT
Cat.#:
12998
Three 6-meter columns
Rtx
®
-TNT2
Cat.#:
12999
Three 6-meter columns
1...,50,51,52,53,54,55,56,57,58,59 61,62,63,64,65,66,67,68,69,70,...152
Powered by FlippingBook