ISO/DIS 9377-4 describes a gas

chromatography/flame ionization detection

(GC/FID) method to analyze total petroleum

hydrocarbons (TPHs) in drinking, surface, waste,

and treated waste water. Previous methods used

Freon

®

extraction, which was harmful to the envi-

ronment. This new method uses less harmful sol-

vents such as pentane, hexane, or cyclohexane for

sample extraction.

Restek now offers mixtures for ISO/DIS 9377-4

analyses. Florisil

®

cleanup to remove polar com-

pounds is accomplished using a 150-250µm

(60/100 mesh) sample preparation column. The

analytical column suggested is either an Rtx

®

-1 or

an Rtx

®

-5 column with dimensions of 10-25m,

0.25-0.53mm ID, and 0.25-1.0µm film thickness.

Standard Mixture Stock Solution

diesel #2 (additive free)

mineral oil (additive free [i.e. USP grade] bp 325–460 or

C18–C32 retention time range)

5,000 µg/mL each in cyclohexane, 1mL per ampule

(prepares 8mL of 1.25µg/µL calibration curve high point)

Total hydrocarbon concentration 10,000 µg/mL

Ea.

5-pk.

10-pk.

31630

31630-510

with data pack

31630-500

31630-520

31730

Quality Control Standard Mixture

diesel #2 (additive free)

mineral oil (additive free [i.e. USP grade] bp 325–460 or

C18–C32 retention time range)

500µg/mL each in acetone, 1mL per ampule (enough to spike

one quality control sample)

Total hydrocarbon concentration 1000µg/mL

Ea.

5-pk.

10-pk.

31631

31631-510

with data pack

31631-500

31631-520

31731

Florisil

®

Cartridge Quality Control

Standard Mixture

Diesel #2 (additive free)

mineral oil (additive free [i.e. USP grade] bp 325–460 or

C18–C32 retention time range)

1000µg/mL each in cyclohexane, 10mL per ampule (enough to

check one Florisil

®

cartridge)

Total hydrocarbon concentration 2000µg/mL

Ea.

5-pk.

10-pk.

31632

31632-510

with data pack

31632-500

31632-520

31732

Standard Mixture of

n

-alkanes for

System Performance Test

n

-decane

n

-hexacosane

n

-dodecane

n

-octacosane

n

-tetradecane

n

-triacontane

n

-hexadecane

n

-dotriacontane

n

-octadecane

n

-tetratriacontane

n

-eicosane

n

-hexatriacontane

n

-docosane

n

-octatriacontane

n

-tetracosane

n

-tetracontane

50µg/mL each in cyclohexane, 1mL per ampule

Ea.

5-pk.

10-pk.

31633

31633-510

with data pack

31633-500

31633-520

31733

Extraction Solvent Stock Solution #1

n

-decane

20µL/L

n

-tetracontane

20mg/L

in cyclohexane, 5mL per ampule (makes 50mL of extraction

solvent, enough for 1 sample)

Ea.

5-pk.

10-pk.

31634

31634-510

with data pack

31634-500

31634-520

31734

Extraction Solvent Stock Solution #2

n

-decane

20µL/L

n

-tetracontane

20mg/L

in cyclohexane, 20mL per ampule (makes 200mL of extraction

solvent, enough for 4 samples)

Ea.

5-pk.

10-pk.

31635

31635-510

with data pack

31635-500

31635-520

31735

Analytical Reference

Materials & Columns

ISO/DIS 9377-4 Water Quality Testing for

Total Petroleum Hydrocarbons (TPH)

by Christopher Cox, R&D Manager

For GC analysis of TPHs in water.

Environmentally safer method than

those performed previously.

new

Rtx

®

-1

(fused silica)

Crossbond

®

100% dimethyl polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25 -60 to 330/350°C 10120

$225

0.25mm 0.50 -60 to 330/350°C 10135

$225

0.32mm 0.25 -60 to 330/350°C 10121

$245

0.32mm 0.50 -60 to 330/350°C 10136

$245

0.53mm 0.25 -60 to 320/340°C 10122

$260

0.53mm 0.50 -60 to 310/330°C 10137

$260

0.53mm 1.00 -60 to 310/330°C 10152

$260

MXT

®

-1

(Silcosteel

®

)

Crossbond

®

100% dimethyl polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25

-60 to 360°C 70120

$235

0.25mm 0.50

-60 to 350°C 70135

$235

0.28mm 0.25

-60 to 360°C 70121

$260

0.28mm 0.50

-60 to 330°C 70136

$260

0.53mm 0.25

-60 to 360°C 70122

$275

0.53mm 0.50

-60 to 330°C 70137

$275

0.53mm 1.00

-60 to 320°C 70152

$275

Always in stock!

Columns

Rtx

®

-5

(fused silica)

Crossbond

®

5% diphenyl/95% dimethyl

polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25 -60 to 330/350°C 10220

0.25mm 0.50 -60 to 330/350°C 10235

0.32mm 0.25 -60 to 330/350°C 10221

0.32mm 0.50 -60 to 330/350°C 10236

0.53mm 0.25 -60 to 320/340°C 10222

0.53mm 0.50 -60 to 310/330°C 10237

0.53mm 1.00 -60 to 310/330°C 10252

MXT

®

-5

(Silcosteel

®

)

Crossbond

®

5% diphenyl/95% dimethyl

polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25

-60 to 360°C 70220

0.25mm 0.50

-60 to 350°C 70235

0.28mm 0.25

-60 to 360°C 70221

0.28mm 0.50

-60 to 330°C 70236

0.53mm 0.25

-60 to 360°C 70222

0.53mm 0.50

-60 to 330°C 70237

0.53mm 1.00

-60 to 325°C 70252

Restek has Rtx

®

-1,

Rtx

®

-5, & Rtx

®

-Wax

columns in stock for

you! There’s no

waiting for the

columns you need.

Stearyl Stearate Test Solution

stearyl stearate

2,000 µg/mL in cyclohexane, 10mL per ampule, (enough to

check one Florisil

®

cartridge)

Ea.

5-pk.

10-pk.

31636

31636-510

with data pack

31636-500

31636-520

31736