Figure 4
A Pinnacle II
™
C18 column resolves all 5 components of a BTEX standard in 15 minutes.
• 3 •
www.restekcorp.comfor
more
info
request the Pinnacle
™
II product flyer
(lit. cat.# #59281).
LC_0161
Environmental Applications
Pinnacle
™
II HPLC columns provide a cost-effective
tool for many traditional methods used in the envi-
ronmental industry, including US Environmental
Protection Agency (EPA) Methods 8310 and 8330, as
well as methods for analyzing BTEX (Figure 4) and
carbamates.
Restek controls Pinnacle
™
II raw material quality
from the very beginning of the silica manufacturing
process. Add our phase bonding and column pack-
ing experience to this high level of quality control,
and you benefit from even better column-to-column
and analysis-to-analysis reproducibility.
Peak List:
1. benzene
2. toluene
3.
o
-xylene
4. ethylbenzene
5.
m
-xylene &
p
-xylene
Sample:
BTEX standard (cat.# 30213)
was diluted 1:10
Inj.:
10µL
Conc.:
200µg/mL
Solvent: acetonitrile
Column:
Pinnacle II C18
Catalog#:
9214565
Dimensions: 150x4.6mm
Particle size: 5µm
Pore size:
110Å
Conditions:
Mobile phase: water:acetonitrile (50:50, v/v)
Flow:
1.0mL/min.
Temp.:
ambient
Det.:
UV @ 254nm
✔
Pinnacle II
™
C8 5µm Columns
Length
1.0mm ID
2.1mm ID
3.2mm ID
4.6mm ID
50mm
9213551
9213552
9213553
9213555
100mm
9213511
9213512
9213513
9213515
150mm
9213561
9213562
9213563
9213565
250mm
9213571
9213572
9213573
9213575
✔
Pinnacle II
™
C18 5µm Columns
Length
1.0mm ID
2.1mm ID
3.2mm ID
4.6mm ID
50mm
9214551
9214552
9214553
9214555
100mm
9214511
9214512
9214513
9214515
150mm
9214561
9214562
9214563
9214565
250mm
9214571
9214572
9214573
9214575
✔
Pinnacle II
™
Phenyl 5µm Columns
Length
1.0mm ID
2.1mm ID
3.2mm ID
4.6mm ID
50mm
9215551
9215552
9215553
9215555
100mm
9215511
9215512
9215513
9215515
150mm
9215561
9215562
9215563
9215565
250mm
9215571
9215572
9215573
9215575
✔
Pinnacle II
™
Cyano 5µm Columns
Length
1.0mm ID
2.1mm ID
3.2mm ID
4.6mm ID
50mm
9216551
9216552
9216553
9216555
100mm
9216511
9216512
9216513
9216515
150mm
9216561
9216562
9216563
9216565
250mm
9216571
9216572
9216573
9216575
Many New Phases Coming Soon!
Check our web site for additional stationary phases in this family of products.
.High backpressure is one of the most
common problems encountered when
performing HPLC analysis. Normal
column backpressure is observed after
a new column has been installed and
equilibrated with the mobile phase.
Unfortunately, this pressure will often
increase with use because of particles
collecting on the column inlet frit.
These particles can be sample impuri-
ties, mobile phase contaminants, or
materials from the injector or
autosampler rotor seal. The presence
of particles can result in increased
backpressure, split peaks, tailing, and
eventually over-pressure shut-down. In
some circumstances, these problems
can be corrected by back-flushing the
column. However, in many cases the
result is an unusable column.
To reduce backpressure problems, all
samples and mobile phase solvents
must be filtered before use, and rotor
seals should be changed on a routine
basis. Along with these preventative
measures, it is advisable to use column
prefilters such as the Trident
™
Direct
column protection system. Particles
build up on the inexpensive, replace-
able frit in the prefilter, instead of the
permanent frit at the head of the
column.
For more information on the Trident
™
Direct guard column system and a
complete product offering, request lit.
cat.# 59314.
Hot Tech Tip