Figure 4

A Pinnacle II

C18 column resolves all 5 components of a BTEX standard in 15 minutes.

• 3 •

www.restekcorp.com

for

more

info

request the Pinnacle

II product flyer

(lit. cat.# #59281).

LC_0161

Environmental Applications

Pinnacle

II HPLC columns provide a cost-effective

tool for many traditional methods used in the envi-

ronmental industry, including US Environmental

Protection Agency (EPA) Methods 8310 and 8330, as

well as methods for analyzing BTEX (Figure 4) and

carbamates.

Restek controls Pinnacle

II raw material quality

from the very beginning of the silica manufacturing

process. Add our phase bonding and column pack-

ing experience to this high level of quality control,

and you benefit from even better column-to-column

and analysis-to-analysis reproducibility.

Peak List:

1. benzene

2. toluene

3.

o

-xylene

4. ethylbenzene

5.

m

-xylene &

p

-xylene

Sample:

BTEX standard (cat.# 30213)

was diluted 1:10

Inj.:

10µL

Conc.:

200µg/mL

Solvent: acetonitrile

Column:

Pinnacle II C18

Catalog#:

9214565

Dimensions: 150x4.6mm

Particle size: 5µm

Pore size:

110Å

Conditions:

Mobile phase: water:acetonitrile (50:50, v/v)

Flow:

1.0mL/min.

Temp.:

ambient

Det.:

UV @ 254nm

Pinnacle II

C8 5µm Columns

Length

1.0mm ID

2.1mm ID

3.2mm ID

4.6mm ID

50mm

9213551

9213552

9213553

9213555

100mm

9213511

9213512

9213513

9213515

150mm

9213561

9213562

9213563

9213565

250mm

9213571

9213572

9213573

9213575

Pinnacle II

C18 5µm Columns

Length

1.0mm ID

2.1mm ID

3.2mm ID

4.6mm ID

50mm

9214551

9214552

9214553

9214555

100mm

9214511

9214512

9214513

9214515

150mm

9214561

9214562

9214563

9214565

250mm

9214571

9214572

9214573

9214575

Pinnacle II

Phenyl 5µm Columns

Length

1.0mm ID

2.1mm ID

3.2mm ID

4.6mm ID

50mm

9215551

9215552

9215553

9215555

100mm

9215511

9215512

9215513

9215515

150mm

9215561

9215562

9215563

9215565

250mm

9215571

9215572

9215573

9215575

Pinnacle II

Cyano 5µm Columns

Length

1.0mm ID

2.1mm ID

3.2mm ID

4.6mm ID

50mm

9216551

9216552

9216553

9216555

100mm

9216511

9216512

9216513

9216515

150mm

9216561

9216562

9216563

9216565

250mm

9216571

9216572

9216573

9216575

Many New Phases Coming Soon!

Check our web site for additional stationary phases in this family of products.

.High backpressure is one of the most

common problems encountered when

performing HPLC analysis. Normal

column backpressure is observed after

a new column has been installed and

equilibrated with the mobile phase.

Unfortunately, this pressure will often

increase with use because of particles

collecting on the column inlet frit.

These particles can be sample impuri-

ties, mobile phase contaminants, or

materials from the injector or

autosampler rotor seal. The presence

of particles can result in increased

backpressure, split peaks, tailing, and

eventually over-pressure shut-down. In

some circumstances, these problems

can be corrected by back-flushing the

column. However, in many cases the

result is an unusable column.

To reduce backpressure problems, all

samples and mobile phase solvents

must be filtered before use, and rotor

seals should be changed on a routine

basis. Along with these preventative

measures, it is advisable to use column

prefilters such as the Trident

Direct

column protection system. Particles

build up on the inexpensive, replace-

able frit in the prefilter, instead of the

permanent frit at the head of the

column.

For more information on the Trident

Direct guard column system and a

complete product offering, request lit.

cat.# 59314.

Hot Tech Tip