Table of Contents Table of Contents
Previous Page  149 / 298 Next Page
Information
Show Menu
Previous Page 149 / 298 Next Page
Page Background

Universal “Y” Press-Tight

®

Connector

with data pack

Figure 3

The Rtx

®

-VGC column resolves chlorobenzene from ethylbenzene, for reliable quantitation.

Figure 2

Methyl-

tert

-butyl-ether,

tert

-butyl alcohol, and closely eluting hydrocarbons separated for

identification by MS.

• 7 •

www.restekcorp.com

1

2

3

4

5

6

7

8

Column:

Rtx

®

-VGC 30m, 0.45mm ID,

2.55µm (cat.# 19408)

Inj.:

splitless injection w/ 0.5 min.

purge off

Compounds at 100ppm

Oven temp.

: 35°C (hold 5 min.)

Carrier gas:

helium @ ~8mL/min.

Detector:

Agilent 5971A

Scan range:

35 to 200amu

1. pentane

2. ethanol

3. 2-methylpentane

4. 3-methylpentane

5. methyl

tert

-butyl ether

6.

tert

-butyl alcohol

7. diisopropyl ether

8. ethyl-

tert

-butyl ether

GC_EV00466

min. .20

.60

1.00 1.40 1.80 2.20 2.60 3.00 3.40 3.80 4.20 4.60

1

2

3

4 5

6/7

8

9

Column:

Rtx

®

-VGC 30m, 0.45mm, 2.55µm (cat.# 19408)

Inj.:

100ppb in 5mL of RO water

Oven temp.:

40°C (hold 2 min.) to 130°C @ 6°C/min.

(hold 0 min.) to 230°C @ 30°C/min. (hold 2 min.)

Carrier gas:

helium @ ~8mL/min.

Detector:

Finnigan PID, make up 7mL/min., purge

7mL/min., set @ 0.35mV, base temperature 200°C

1. benzene

2.

α

,

α

,

α

-trifluorotoluene

3. toluene

4. ethylbenzene

5. chlorobenzene

6.

m

-xylene

7.

p

-xylene

8.

o

-xylene

9. 4-bromo-1-chlorobenzene

GC_EV00468

min.0

5

10

15

20

Rtx

®

-VGC

(Fused Silica)

Stable to 260°C

ID

df (µm)

temp. limits

30-Meter

60-Meter

75-Meter

105-Meter

0.25mm 1.40 -40 to 240/260°C 19415

19416

0.32mm 1.80 -40 to 240/260°C 19419

19420

0.45mm 2.55 -40 to 240/260°C 19408

19409

0.53mm 3.00 -40 to 240/260°C 19485

19488

19474

19489

ID

df (µm)

temp. limits

20-Meter

40-Meter

0.18mm 1.00 -40 to 240/260°C 49414

49415

diisopropyl ether

2,000µg/mL

ethyl-

tert

-butyl ether

2,000

tert

-amyl methyl ether

2,000

tert

-butyl alcohol

10,000

methyl

tert

-butyl ether

2,000

In P&T methanol, 1mL/ampul

California Oxygenates Mix

Each

5-pk.

10-pk.

30465

30465-510

30465-500

30465-520

30565

Universal “Y” Press-Tight

®

Connectors

• Split sample flow onto two different columns.

• Split a single column flow into two detectors.

• Perform confirmational analysis with a single

injection.

• Fits 0.18, 0.25, 0.32, & 0.53mm ID columns.

qty.

cat.#

price

ea.

20405

3-pk.

20406

Straight Silcosteel

®

Tubing

• Ideal for transfer lines, adsorbent traps, and thermal desorption tubes.

• Available in

1

/

8

- and

1

/

4

-inch OD.

• Easily cut to specific lengths.

18" (457mm) Length

ID

OD

qty.

cat.#

price

0.085" (2.16mm)

1

/

8

" (3.18mm)

ea.

20575

0.085" (2.16mm)

1

/

8

" (3.18mm)

5-pk.

20576

0.210" (5.33mm)

1

/

4

" (6.35mm)

ea.

20577

0.210" (5.33mm)

1

/

4

" (6.35mm)

5-pk.

20578

Standards for Underground

Storage Tank Monitoring

(UST)

Monitoring underground storage tanks (UST)

for leaks continues. Many states continue to

modify existing analytical methods, with several

states now using risk-based management of

compounds involved. These new methods often

pose challenges to the analyst, and require

unique mixtures for calibration and matrix

spike samples.

Restek continues to monitor the situation and

respond with calibration mixtures to meet

these needs. For our extensive selection of

chemical standards for UST analyses, please

refer to our 2002

Chromatography Products

Catalog

(lit. cat. #59662). For mixtures not

listed there, please contact Technical Service at

800-356-1688 or 814-353-1300, ext. 4, or

contact your local Restek representative.

Restek is your #1 source for pesticide reference materials!

Extensive selection of stock mixtures and single-component solutions.

Custom mixtures made to your exact specifications.

Fax our reference materials department (814-353-1309) or contact your local Restek