Table of Contents Table of Contents
Previous Page  155 / 298 Next Page
Information
Show Menu
Previous Page 155 / 298 Next Page
Page Background

with data pack

with data pack

• 13 •

www.restekcorp.com

Table I

Small relative standard deviations for calibration factors show a Drilled Uniliner

®

inlet liner efficiently

transfers the sample to the column.

Relative Standard Deviation (%)

CLPesticides

CLPesticides2

Column

Column

α

-BHC

7.0

7.5

γ

-BHC

3.3

3.8

β

-BHC

10.2

9.6

δ

-BHC

6.0

7.1

heptachlor

4.2

10.9

aldrin

2.3

1.2

heptachlor epoxide

10.7

8.6

γ

-chlordane

6.8

6.7

α

-chlordane

8.3

6.7

4,4' DDE

2.3

3.3

endosulfan I

9.2

8.3

dieldrin

7.6

6.6

endrin

4.9

5.3

4,4' DDD

2.7

4.1

endosulfan II

9.9

9.7

4,4' DDT

3.8

2.4

endrin aldehyde

12.3

13.3

methoxychlor

10.2

10.8

endosulfan sulfate

9.3

10.6

endrin ketone

7.9

5.3

DI Liners for Agilent 5890/6890 GCs

(For 0.25/0.32/0.53mm ID Columns)

ID*/OD &

Length (mm)

cat.#/price

ea.

cat.#/price

5-pk.

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054

21055

Siltek

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054-214.1 21055-214.5

Siltek

1mm Drilled Uniliner

®

1.0 ID

6.3 OD x 78.5

21390-214.1 21391-214.5

Standard:

cat#. 32292, 8/16/80µg/mL

in hexane:toluene (1:1)

Calibration curve standards:

5/10/50ng/mL in hexane

20/40/200ng/mL in hexane

80/160/800ng/mL in hexane

Uniliner

®

Inlet Liners for Agilent GCs

Chlorinated pesticides listed in US EPA Method 8081.

Stx

-CLPesticides

(Fused Silica with Siltek

deactivation)

ID

df (µm)

temp. limits

15-Meter

30-Meter

0.25mm

0.25

-60 to 310/330°C

11540

11543

0.32mm

0.50

-60 to 310/330°C

11541

11544

0.53mm

0.50

-60 to 310/330°C

11542

11545

Stx

-CLPesticides2

(Fused Silica with Siltek

deactivation)

ID

df (µm)

temp. limits

15-Meter

30-Meter

0.25mm

0.20

-60 to 310/330°C

11440

11443

0.32mm

0.25

-60 to 310/330°C

11441

11444

0.53mm

0.42

-60 to 310/330°C

11442

11445

*Nominal ID at syringe needle expulsion point.

decachlorobiphenyl

2,4,5,6-tetrachloro-

m

-xylene

200µg/mL each in acetone, 1mL/ampul

Pesticide Surrogate Mix

Each

5-pk.

10-pk.

32000

32000-510

32000-500

32000-520

32100

aldrin

8µg/mL

α

-BHC

8

β

-BHC

8

δ

-BHC

8

γ

-BHC (lindane)

8

α

-chlordane

8

γ

-chlordane

8

4,4'-DDD

16

4,4'-DDE

16

4,4'-DDT

16

dieldrin

16

endosulfan I

8

endosulfan II

16

endosulfan sulfate

16

endrin

16

endrin aldehyde

16

endrin ketone

16

heptachlor

8

heptachlor epoxide (B)

8

methoxychlor

80

In hexane:toluene (1:1), 1mL/ampul

Organochlorine

Pesticide Mix AB #2

Each

5-pk.

10-pk.

32292

32292-510

32292-500

32292-520

32392

The Drilled Uniliner

®

inlet liner is the

first inlet liner to allow direct injections

in EPC systems!

INNOVATION

linearity values (% RSD) obtained using a Drilled

Uniliner

®

liner and Rtx

®

-CLPesticides columns.

Equivalent results are obtained with

Stx

-CLPesticides columns.

When using a Drilled Uniliner

®

liner, the efficient

transfer of sample from the injection port to the

column might allow more nonvolatile material to

enter the column. For many samples this will not be

an issue, especially if solid phase cleanup is per-

formed. Using a guard column will help maintain

the analytical column. When necessary, the guard

column can be trimmed to remove the portion

where the nonvolatile material collects (usually the

first 6-12 inches).

Conclusion

The Drilled Uniliner

®

liner provides the advantages

of both direct and splitless injection liners. The liner

provides a more inert sample pathway to transfer

the sample from the injector to the analytical col-

umn, and it helps eliminate injection port discrimi-

nation. A Drilled Uniliner

®

liner will reduce the

detection limits for injections made on a splitless

injection port, without the need for an on-column

injector.

O n l i n e

a t

www. r e s t e k c o r p . c om

Ordering