Table of Contents Table of Contents
Previous Page  49 / 628 Next Page
Information
Show Menu
Previous Page 49 / 628 Next Page
Page Background www.restek.com

47

GC COLUMNS |

GENERAL-PURPOSE COLUMNS

Rtx®-50, Rtx®-65

Rtx®-50 Columns

(fused silica)

(midpolarity phase; Crossbond® phenyl methyl polysiloxane)

• General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters,

sterols.

• Temperature range: 40 °C to 320 °C.

• Equivalent to USP G3 phase.

The high thermal stability of Rtx®-50 columns makes dual-column analysis possible

with common phases such as Rtx®-1 or Rtx®-5MS.

similar

phases

HP-50+, CP-Sil 24 CB, SPB-50, AT-50, 007-17

Rtx®-65 Columns

(fused silica)

(mid- to high-polarity phase; Crossbond® diphenyl dimethyl polysiloxane)

• General-purpose columns for phenols, fatty acids, triglycerides.

• Temperature range: 50 °C to 300 °C.

The Rtx®-65 phase contains the highest phenyl content of any bonded stationary

phase available to improve separation of aromatic compounds through increased

phase-analyte interaction. A unique polarity makes these columns ideal for a vari-

ety of analyses, from phenols to FAMEs. As a confirmation column for EPA Method

604 phenols, an Rtx®-65 column produces a different elution order compared to the

primary Rtx®-5 column. Rtx®-65 columns elute FAMEs according to equivalent chain

length, similar to bonded Carbowax® columns, but the Rtx®-65 phase does not suffer

the thermal stability limitations of other polar stationary phases.

similar

phases

007-65HT

Rtx®-50 Structure

CH

3

Si

100%

O

Rtx®-65 Structure

CH

3

CH

3

Si

35%

O

Si

65%

O

crossbond® technology

Reduces bleed, prolongs column

lifetime, and allows rejuvenation

through solvent rinsing.

Similar to: (50%-phenyl)-methylpolysiloxane

Similar to: (65%-phenyl)-methylpolysiloxane

also

available

Metal MXT® Columns

Rugged, flexible, Siltek®-treated stainless

steel tubing; inertness comparable to

fused silica tubing.

MXT®-50 columns...................

. page 109

also available

Rtx®-65TG Columns

Tested specifically for triglycerides.

See

page 89

.

30-Meter

ID

df

temp. limits

cat.#

price

0.25 mm 0.25 µm

50 to 300 °C

17023

0.50 µm 50 to 280/300 °C

17038

1.00 µm 50 to 260/280 °C

17053

0.32 mm 0.25 µm

50 to 300 °C

17024

0.50 µm 50 to 280/300 °C

17039

1.00 µm 50 to 260/280 °C

17054

0.53 mm 1.00 µm 50 to 250/270 °C

17055

15-Meter

30-Meter

60-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.25 µm 40 to 300/320 °C

10520

10523

10526

0.50 µm 40 to 290/310 °C

10535

10538

10541

1.00 µm 40 to 280/300 °C

10550

10553

0.32 mm 0.25 µm 40 to 300/320 °C

10521

10524

10527

0.50 µm 40 to 290/310 °C

10536

10539

10542

1.00 µm 40 to 280/300 °C

10551

10554

10557

0.53 mm 0.25 µm 40 to 280/300 °C

10522

0.50 µm 40 to 270/290 °C

10537

10540

10543

0.83 µm 40 to 270/290 °C

10569

1.00 µm 40 to 260/280 °C

10552

10555

10558

1.50 µm 40 to 250/270 °C

10567

10570

10-Meter

20-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

0.18 mm 0.20 µm 40 to 310/330 °C

40501

40502

0.40 µm 40 to 300/320 °C

40510

40511