Table of Contents Table of Contents
Previous Page  54 / 628 Next Page
Information
Show Menu
Previous Page 54 / 628 Next Page
Page Background

52

www.restek.com

GC COLUMNS |

GENERAL-PURPOSE COLUMNS

Rtx®-624

Rtx®-624 Structure

x

y

Si

O

(CH

2

)

3

CH

3

Si

O

CH

3

z

CH

3

CH

3

Si

O

C N

Similar to: (6%-cyanopropylphenyl)-methylpolysiloxane

also

available

Metal MXT® Columns

Rugged, flexible, Siltek®-treated stainless

steel tubing; inertness comparable to

fused silica tubing.

MXT®-624 columns..............

. page 111

1 2 3 4

5

6

7

8

9

10

11

1213

14

15

16

17 18

19

20

21

22

23

24

25

26

27

28

29

30

31

32,33

34

35 36

37

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Time (min)

Volatiles US EPA Method 624 on Rtx®-624

GC_EV00701

Column

Rtx®-624, 40 m, 0.18 mm ID, 1.00 µm (cat.# 40925)

Sample

624 Internal Standard Mix (cat.# 30023)

624 Surrogate Standard Mix (cat.# 30243)

Volatiles MegaMix™, EPA Method 624 (cat.# 30497)

Conc.:

compounds at 50 ppb (IS @ 40ppb) in 5mL of RO water

Injection

purge and trap split (split ratio 40:1)

Inj. Temp.:

250 °C

Purge and Trap

Instrument:

Tekmar LSC-3100 Purge and Trap

Trap Type:

Vocarb 3000 (type K)

Purge:

11 min @ ambient, flow 40 mL/min

Dry Purge:

1 min, flow 40 mL/min

Desorb Preheat

Temp.:

245 °C

Desorb:

2 min @ 250 °C, flow 10 mL/min

Bake:

8 min @ 260 °C

Interface Connection: injection port

Transfer Line Tubing: Silcosteel® transfer line, 1mm ID sleeve

Oven

Oven Temp.:

50 °C (hold 4 min) to 100 °C at 12 °C/min to 230 °C

at 27 °C/min (hold 2 min)

Carrier Gas

He, constant flow

Flow Rate:

1.1 mL/min

Dead Time:

2.06 min @ 50 °C

Detector

Agilent 5971A GC/MS

Transfer Line Temp.:

280 °C

Analyzer Type:

Quadrupole

Tune Type:

PFTBA/BFB

Ionization Mode:

EI

Scan Range:

35-260 amu

Notes

(MCS bypassed using Silcosteel® tubing)

Peaks

1. Chloromethane

2. Vinyl chloride

3. Bromomethane

4. Chloroethane

5. Trichlorofluoromethane

6. 1,1-Dichloroethene

7. Methylene Chloride

8.

trans

-1,2-Dichloroethene

9. 1,1-Dichloroethane

10. Bromochloromethane

11. Chloroform

12. 1,1,1-Trichloroethane

13. Pentafluorobenzene

14. Carbon Tetrachloride

15. Benzene

16. 1,2-Dichloroethane

17. Fluorobenzene

18. Trichloroethene

19. 1,2-Dichloropropane

20. Bromodichloromethane

21. 2-Chloroethyl vinyl ether

22.

cis

-1,3-Dichloropropene

23. Toluene

24. 2-Bromo-1-chloropropane

25. 1,1,2-Trichloroethane

26. Tetrachloroethene

27. Dibromochloromethane

28.

trans

-1,3-Dichloropropene

29. Chlorobenzene

30. Ethylbenzene

31. Bromoform

32. 1,4-Dichlorobutane

33. 4-Bromofluorobenzene

34. 1,1,2,2-Tetrachloroethane

35. 1,3-Dichlorobenzene

36. 1,4-Dichlorobenzene

37. 1,2-Dichlorobenzene

Rtx®-624 Columns

(fused silica)

(low- to midpolarity phase)

• Application-specific columns for volatile organic pollutants. Recommended

in U.S. EPA methods for volatile organic pollutants.

• Temperature range: -20 °C to 240 °C.

• Equivalent to USP G43 phase.

The unique polarity of the Rtx®-624 column makes it ideal for analyzing volatile or-

ganic pollutants. Although the Rtx®-502.2 column is recommended in many methods,

the Rtx®-624 column offers better resolution of early eluting compounds. The Rtx®-624

phase produces greater than 90% resolution of the first six gases in EPA Methods 8260

and 524.2. This stationary phase is especially well-suited for EPA Method 524.2 since it

resolves 2-nitropropane from 1,1-dichloropropanone, which share quantification ion

m/z 43 and must be separated chromatographically.

similar

phases

DB-1301, DB-624, DB-624UI, VF-1301ms,

VF-624ms, CP-1301, ZB-624

*Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.

30-Meter

60-Meter

75-Meter

105-Meter

ID

df

temp. limits* cat.#

price

cat.#

price

cat.#

price

cat.#

price

0.25 mm 1.40 µm -20 to 240 °C 10968

10969

0.32 mm 1.80 µm -20 to 240 °C 10970

10972

0.53 mm 3.00 µm -20 to 240 °C 10971

10973

10974

10975

20-Meter

40-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

0.18 mm 1.00 µm -20 to 240 °C

40924

40925