GC COLUMNS |

GENERAL-PURPOSE COLUMNS

Rtx®-1301

Rtx®-1301 (G43) Columns

(fused silica)

(low- to midpolarity phase)

• General-purpose columns for residual solvents, alcohols, oxygenates, and volatile

organic compounds.

• Temperature range: -20 °C to 280 °C.

• Equivalent to USP G43 phase.

Many analysts feel the Rtx®-1301 column has the best cyanosiloxane bonded station-

ary phase available, with no other column manufacturer providing lower bleed, longer

lifetime, or better inertness. Our polymer is fully characterized to ensure long-term

reproducibility, column-to-column consistency, and low bleed—even with sensitive

detectors such as ECDs and MSDs.

*Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.

15-Meter

30-Meter

60-Meter

75-Meter

105-Meter

ID df

temp. limits* cat.#

price

cat.#

price

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.25 µm -20 to 280 °C 16020

16023

16026

0.50 µm -20 to 270 °C

16038

1.00 µm -20 to 260 °C

16053

16056

1.40 µm -20 to 240 °C

16016

0.32 mm 0.25 µm -20 to 280 °C 16021

16024

0.50 µm -20 to 270 °C

16039

16042

1.00 µm -20 to 260 °C

16054

16057

1.50 µm -20 to 250 °C 16066

16069

16072

1.80 µm -20 to 240 °C

16092

16093

0.53 mm 0.25 µm -20 to 280 °C

16025

0.50 µm -20 to 270 °C

16040

16043

1.00 µm -20 to 260 °C 16052

16055

16058

1.50 µm -20 to 250 °C

16070

3.00 µm -20 to 240 °C

16085

16088

16076

16091

Rtx®-1301 with Integra-Guard® Columns

Description

qty.

cat.#

price

30 m, 0.53 mm ID, 3.00 µm Rtx-1301 w/5 m Integra-Guard Column

ea.

16085-126

Rtx®-1301 Structure

x

y

Si

O

(CH

2

)

3

CH

3

Si

O

CH

3

z

CH

3

CH

3

Si

O

C N

Similar to: (6%-cyanopropylphenyl)-methylpolysiloxane

Get the protection without the connection!

Integra-Guard® Built-In Guard Column

similar

phases

DB-1301, DB-624, DB-624UI, VF-1301ms,

VF-624ms, CP-1301, ZB-624

• No leaks for a more robust method.

• No column connections for easier, faster maintenance.

• No peak distortions due to connector dead volume and thermal capacity.

0

10

20

1

2

3

4

5

Time (min)

USP <467> Residual Solvents on Rtx®-1301 (G43) by Static Headspace

GC_PH00810

Column

Rtx®-1301 w/5 m Integra-

Guard® , 30 m, 0.53 mm

ID, 3.00 µm

(cat.# 16085-126)

Sample

USP <467> Calibration

Mixture #5 (cat.# 36007)

Diluent:

DMSO

Conc.:

To each 22 mL headspace

vial 5ml water, ~ 1.0 g of

sodium sulfate and 100

µL of stock standard were

added.

Injection

headspace-loop split

(split ratio 2:1)

Headspace-Loop

Inj. Port Temp.:

180 °C

Instrument:

Teledyne Tekmar HT3

Inj. Time:

1.0 min

Transfer Line Temp.: 150 °C

Valve Oven Temp.:

150 °C

Standby flow rate:

10 mL/min

Sample Temp.:

80 °C

Platen temp

equil. time:

2.0 min

Sample Equil. Time: 15.0 min

Mixer time:

2.0 min

Mixing level:

5

Mixer stabilize

time:

0.5 min

Vial Pressure:

15 psi

Pressurize Time: 2.0 min

Pressure

Equilibration

Time:

0.5 min

Loop Pressure:

5 psi

Loop Fill Time:

2.0 min

Loop fill equil.

time:

0.5 min

Oven

Oven Temp.:

40 °C (hold 20 min)

to 240 °C at 25 °C/min (hold

10 min)

Carrier Gas

He, constant flow

Flow Rate:

5 mL/min

Detector

FID@ 250 °C

Make-up Gas

Flow Rate:

45 mL/min

Notes

FID conditions:

hydrogen flow: 40 mL/min

air flow: 450 mL/min

Peaks

t

R

(min)

Conc. (µg/mL)

1. Dichloromethane

5.110

12.0

2. Chloroform

9.285

1.2

3. Benzene

11.173

0.04

4. Trichloroethylene

14.647

1.6

5. 1,4-Dioxane

17.436

7.6

also

available