Table of Contents Table of Contents
Previous Page  46 / 628 Next Page
Information
Show Menu
Previous Page 46 / 628 Next Page
Page Background

44

www.restek.com

GC COLUMNS |

GENERAL-PURPOSE COLUMNS

Rtx®-5MS

Food Packaging Volatiles by Purge & Trap GC-MS on Rtx®-5MS

GC_FF00462

Column

Rtx®-5MS, 30 m, 0.25 mm ID, 1.00 µm

(cat.# 12653)

Sample

Overwrap, inner bowl

Injection

Purge and trap split (split ratio 20:1)

Liner:

1 mm ID

Inj. Temp.:

250 °C

Purge and Trap

Instrument:

Tekmar LSC-3100 purge & trap

Trap Type:

Vocarb 3000, type K

Purge:

10 min @ 60 °C, flow 40 mL/min

Dry Purge:

3 min, flow 40 mL/min

Desorb Preheat

Temp.:

220 °C

Desorb:

2 min @ 245 °C, flow 40 mL/min

Bake:

6 min @ 230 °C

Interface

Connection:

Injection port

Transfer Line

Tubing:

Siltek®/Sulfinert® tubing (cat.# 22501)

Oven

Oven Temp.:

50 °C to 92 °C at 3 °C/min to 220 °C at

20 °C/min (hold 1 min)

Carrier Gas

He, constant flow

Flow Rate:

1 mL/min

Linear Velocity:

36 cm/sec

Detector

MS

Mode:

Scan

Source Temp.:

280 °C

Electron Energy: EI @ 70 eV

Scan Range:

35-260 amu

Instrument

HP6890 GC & 5973 MSD

Peaks

1. Ethyl acetate

2. Toluene

3. 4-Heptanone

4.

n

-Butyl ether

5. Styrene

6. Alkanes

Rtx®-5MS Structure

CH

3

CH

3

Si

95%

O

Si

5%

O

similar

phases

DB-5, HP-5, HP-5MS, Ultra-2, SPB-5,

CP-Sil 8 CB, ZB-5

Rtx®-5MS with Integra-Guard® Columns

Description

qty.

cat.#

price

15 m, 0.25 mm ID, 0.25 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12620-124

15 m, 0.25 mm ID, 0.50 µm Rtx-5MS w/10 m Integra-Guard Column

ea.

12635-127

30 m, 0.25 mm ID, 0.10 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12608-124

30 m, 0.25 mm ID, 0.25 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12623-124

30 m, 0.25 mm ID, 0.25 µm Rtx-5MS w/10 m Integra-Guard Column

ea.

12623-127

30 m, 0.25 mm ID, 0.50 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12638-124

30 m, 0.25 mm ID, 0.50 µm Rtx-5MS w/10 m Integra-Guard Column

ea.

12638-127

30 m, 0.32 mm ID, 0.25 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12624-125

30 m, 0.32 mm ID, 1.00 µm Rtx-5MS w/5 m Integra-Guard Column

ea.

12654-125

Get the protection without the connection!

Integra-Guard® Built-In Guard Column

Rtx®-5MS—Low-Bleed GC-MS Columns

(fused silica)

(low-polarity phase; Crossbond® diphenyl dimethyl polysiloxane)

• General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons,

PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.

• Column specifically tested for low-bleed performance.

• Temperature range: -60 °C to 350 °C.

• Equivalent to USP G27 and G36 phases.

Note: The DB-5MS is a silarylene-based polymer equivalent to the Rxi-5Sil MS.

*Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.

15-Meter

30-Meter

60-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.10 µm -60 to 330/350 °C 12605

12608

12611

0.25 µm -60 to 330/350 °C 12620

12623

12626

0.50 µm -60 to 330/350 °C 12635

12638

12641

1.00 µm -60 to 325/350 °C 12650

12653

0.32 mm 0.10 µm -60 to 330/350 °C 12606

12609

0.25 µm -60 to 330/350 °C 12621

12624

12627

0.50 µm -60 to 330/350 °C

12639

12642

1.00 µm -60 to 325/350 °C

12654

0.53 mm 0.50 µm -60 to 320/340 °C 12637

12640

1.00 µm -60 to 320/340 °C 12652

12655

1.50 µm -60 to 310/330 °C 12667

12670

We carefully manage inventory so we have

what you need when you need it.