Table of Contents Table of Contents
Previous Page  43 / 628 Next Page
Information
Show Menu
Previous Page 43 / 628 Next Page
Page Background www.restek.com

41

GC COLUMNS |

GENERAL-PURPOSE COLUMNS

Rtx®-1

Rtx®-1 Structure

CH

3

CH

3

Si

100%

O

Rtx®-1 with Integra-Guard® Column

crossbond® technology

Reduces bleed, prolongs column lifetime, and

allows rejuvenation through solvent rinsing.

Description

qty.

cat.#

price

30 m, 0.25 mm ID, 0.25 µm Rtx-1 w/5 m Integra-Guard Column

ea.

10123-124

30 m, 0.53 mm ID, 1.00 µm Rtx-1 w/5 m Integra-Guard Column

ea.

10155-126

30 m, 0.53 mm ID, 5.00 µm Rtx-1 w/5 m Integra-Guard Column

ea.

10179-126

Similar to: (100%-methyl)-polysiloxane

also

available

Metal MXT® Columns

Rugged, flexible, Siltek®-treated stainless

steel tubing; inertness comparable to

fused silica tubing.

See

page 107

.

Fused Silica Capillary & PLOT Column

Ferrule Guide

free literature

Analyze ppb Level Sulfur

Compounds

Using an Rt®-XLSulfur

Micropacked GC Column or an Rtx®-1

Thick Film Capillary GC Column

Download your free copy from

www.restek.com

lit. cat.#

PCAN1499-UNV

GC Column ID

Ferrule ID

0.15 mm

0.4

0.18 mm

0.4

0.25 mm

0.4

0.32 mm

0.5

0.53 mm

0.8

Sulfur in Gasoline on Rtx®-1

GC_PC00198

Column

Rtx®-1, 30 m, 0.32 mm ID, 4.0 µm

(cat.# 10198)

Sample

Gasoline containing 300 ppm

total sulfur

Injection

Inj. Vol.:

1 µL split (split ratio 10:1)

Inj. Temp.:

275 °C

Oven

Oven Temp.:

40 °C (hold 3 min) to 275 °C at 10

°C/min (hold 5 min)

Carrier Gas

He, constant flow

Flow Rate:

2.5 mL/min

Linear Velocity:

70 cm/sec

Detector

SCD@ 275 °C

Peaks

1. Thiophene

2. 2-Methylthiophene

3. 3-Methylthiophene

4. 2-Ethylthiophene

5. Alkylthiophenes

6. Benzothiophene

7. Methylbenzothiophenes

8. Dimethylbenzothiophenes

Rtx®-1 Columns

(fused silica)

(nonpolar phase; Crossbond® dimethyl polysiloxane)

• General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor

mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur

compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates.

• Long lifetime and very low bleed at high operating temperatures.

• Temperature range: -60 °C to 350 °C.

• Equivalent to USP G1, G2, G38 phases.

similar

phases

HP-1, DB-1, CP-Sil 5 CB, ZB-1

*Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.

15-Meter

30-Meter

60-Meter

105-Meter

ID df

temp. limits*

cat.#

price

cat.#

price

cat.#

price

cat.#

price

0.25 mm 0.10 µm -60 to 330/350 °C 10105

10108

10111

0.25 µm -60 to 330/350 °C 10120

10123

10126

10129

0.50 µm -60 to 330/350 °C 10135

10138

10141

10144

1.00 µm -60 to 320/340 °C 10150

10153

10156

10159

0.32 mm 0.10 µm -60 to 330/350 °C 10106

10109

10112

0.25 µm -60 to 330/350 °C 10121

10124

10127

0.50 µm -60 to 330/350 °C 10136

10139

10142

1.00 µm -60 to 320/340 °C 10151

10154

10157

10160

1.50 µm -60 to 310/330 °C 10166

10169

10172

10175

3.00 µm -60 to 280/300 °C 10181

10184

10187

10190

4.00 µm -60 to 280/300 °C

10198

5.00 µm -60 to 260/280 °C 10176

10178

10180

0.53 mm 0.10 µm -60 to 320/340 °C 10107

10110

0.25 µm -60 to 320/340 °C 10122

10125

10128

0.50 µm -60 to 310/330 °C 10137

10140

10143

1.00 µm -60 to 310/330 °C 10152

10155

10158

1.50 µm -60 to 310/330 °C 10167

10170

10173

3.00 µm -60 to 270/290 °C 10182

10185

10188

10189

5.00 µm -60 to 270/290 °C 10177

10179

10183

10194

7.00 µm -60 to 240/260 °C 10191

10192

10193

10-Meter

20-Meter

40-Meter

ID df

temp. limits

cat.#

price

cat.#

price

cat.#

price

0.18 mm 0.20 µm -60 to 330/350 °C 40101

40102

40103

0.40 µm -60 to 330/340 °C 40110

40111

40112