Chromtech SuppierOperatingManuals - page 4

valves V1~V5 and Programmable Logic Control
PLC
together with
Touch Screen Panel TP170.
The system is controlled by two modes: manually control or
automatically control.
When manually operation, Pumping, Wet or Dry gas filling can be
done by single Step operation.
When automatically
the system can run automatically step by step
following predefined requirements (including vacuum pressure limit,
Wet gas clean cycle counts, Dry gas clean cycle counts, Vent
Off-Delay.) No manually operation is necessary and running status can
be displayed through indicator light and high vacuum gauge. In the
automatic cycle
vacuum pump keeps running and merely various
valves need to be switched on or off as required.
Switching between automatic and manual control is processed by
pressing different touch switches
manually operations include Run-m,
Pumping, Fill wet gas, Fill Dry gas, Reset and Return touch keys.
Under auto mode it can be started by pressing Run-A touch key. Reset
key is used to break and reset when the system is running. P1~P3 are
display pressure/vacuum values state
which are pre-set
Note
zero
air-filling pressure limit for P1 is 30 psi
P2 means vacuum limit for
pumping conversion to next filling
P3
final vacuum pressure
value
),
and can be modified when needed
Cycle Value and Vent
4
1,2,3 5,6,7,8,9,10,11,12,13,14,...269