MRC-2014Hot.svg - page 432

Operating Instructions WBL-118 Refrigerated bath and circulator
18
3.1.3 The key functions and navigate the menu (Fig 4)
There’re 4 keys as follows. The function and their operation are summarized and listed in the table:
3.2 Set the working parameters
1) Set the working temperature
Refer to No.2 in the table.
2) Set high temperature limit value
Press
for more than 2 seconds until
Ht
is displayed. Press
to enter
Ht
setting. Original
KEY NO FUNCTION OPERATION
REMARKS
1
Initiate or
terminate pump
circulating
Press and hold
the key for more
than 2 seconds.
Temperature regulating is possible only if the circulating
pump is initiated.
2
Set the working
temperature
Press the button
for less than 1
second.
After showing
SEt
, press
to enter, change the
digits by pressing
, accept the setting
by pressing
.
3
Set the working
parameters
Press and hold
the key for more
than 2 seconds.
a)
Ht
is first displayed, press
for
Lt
,
Cool
,
Auto
,
Atc
and
dEFt
, use
ESc
for exit;
b) Press
to enter for change of a definite
setting of the working parameter, for example
Ht
.
Change the digits or setting by pressing
, accept the setting by pressing
, or
confirmed and exit automatically in 4 seconds.
4
Move between
settings or
increase the
value
Press the key
shortly
5
Move between
settings or
decrease the
value
Press the key
shortly
351
1...,422,423,424,425,426,427,428,429,430,431 433,434,435,436,437,438,439,440,442-443,444-445,...
Powered by FlippingBook