byChristopher English, Environmental InnovationsChemist, &BradRightnour, Instrument InnovationsManager
EZ No-Vent
GC Column-
Mass Spectrometer Connector
ChangeColumns inMinutes,Without Venting
Easy to install andmaintain—no special tools or extra plumbing required.
Gold plated for inertness.
100µm ID transfer line keeps analytes focused.
Lower cost than other “no-vent” fittings.
We designed our new EZ No-Vent
GC column-mass
spectrometer connector to be simple and easy to
use. After studying user feedback concerning our
EZ-Vent
2000 connector, we re-engineered the
connector fitting for even better performance.
A critical orifice in the EZ No-Vent
connectormin-
imizes the amount of oxygen allowed into theMS
source, eliminating the need for purge gas and
enabling you to skip the lengthy vent and pump-
down cycle otherwise requiredwhen youmake a
column change. This can save nearly a day of
downtime with each column change. The EZ No-
Vent
connector easily attaches to theMS source
without special tools or extra plumbing. Figure 1
shows the fitting installed and ready for use.
We tested the EZ No-Vent
connector, using highly
volatile gaseous sample components that are very
susceptible to tailing in the presence of dead vol-
ume. We operated the system as a purge-and-trap
GC/MS system, initially with a split at the injection
port and the column inserted directly into theMS
interface. Next, we included the EZ No-Vent
con-
nector at theMS interface. We anticipated that any
dead volume in this fitting would produce signifi-
cant tailing and broader peaks, relative to the direct
connection. Peak shape was excellent using the new
fitting.
Similarly, we used an application-specific test to
evaluate the ability of theMS to stabilize after we
changed columns without venting. Againwe used a
purge-and-trap system, halogenated volatiles as the
sample, and an Rtx
®
-624 column to separate the
analytes. We acquired Figure 2a at 08:12 AM, then
changed the column. We acquired Figure 2b 76
minutes later, at 09:28 AM. Note the excellent peak
shapes and responses. In the interval between the
two analyses we verifiedMSD tuning, and the sys-
tem passed bromofluorobenzene (BFB) criteria.
Subsequent detailed investigations have established
that the EZ No-Vent
connector will allow several
column changes in a single day, with no harm to
theMS or loss of data quality.
If you’re tired of waiting for yourMS to stabilize, we
highly recommend you use an EZ No-Vent
connec-
tor. It will reduce yourMS downtime, saving you
money, and increase your sample throughput—
making youmoney.
Figure 1
MS transfer line installed in an EZNo-Vent
connector. Connection can bemade quickly,
without special tools.
Figure 2
Acquire a samplewithin two hours of changing columns, using an EZNo-Vent
connector.
expanded view
Description
qty.
cat.#
price
EZNo-Vent
Connector Kit for Agilent 5971/5972 and 5973GC/MS
(Kit includes: EZNo-Vent
Connector, 0.4mm ID ferrules for connecting capillary
column, 0.4mm ID ferrules for connecting transfer line, 100µm deactivated transfer
line (3 ft.), and EZNo-Vent
column plug and nut.)
kit
21323
Replacement ferrules for connecting capillary column to EZNo-Vent
:
0.4mm ID
2-pk.
21015
0.5mm ID
2-pk.
21016
Replacement ferrules for connecting transfer line to
EZ-No Vent
: 0.4mm ID
2-pk.
21043
Replacement deactivated transfer line: 100µm ID
3 ft.
21018
Replacement EZNo-Vent
ColumnNut
5-pk.
21900
Replacement EZNo-Vent
Plug
2-pk.
21915
Open-endWrenches (
1
/
4
" x
5
/
16
")
2-pk.
20110
3 4 5 6 7 8 9 10 11 12
20 min.
13 14 15
19 18 17 16
5 6
4 3
7 8 9 10 11 12 13 14 15 16 17 18 19
min.
20
GC_EV00659c
GC_EV00659d
Restek
Innovation!
Rtx
®
-624 60m, 0.25mm ID, 1.4µm (cat# 10969)
Halogenated Volatiles@ 200 ppb in 5mL/ROwater.
502.2 CalibrationMix#1 (gases)
cat# 30042
502.2 CalibrationMix#2
cat# 30043
BTEX standard
cat# 30213
2b—acquired at 9:28am
Ez-No Vent
, acquired 76min. after installing new column
Inj.:
purge& trap
GC:
Agilent 6890
Inj. temp.:
300°C
Carrier gas:
helium, constant flow
Flow rate:
1.0mL/min.
Oven temp.:
60°C (hold 15min.) to
220°C@ 30°C/min.
(hold 1min.)
Det:
Agilent 5973GC/MS
Transfer line temp.:
280°C
Scan range:
35-550 amu
Tune:
BFB
Ionization:
EI
for
more
info
request lit. cat.# 59498.
2a—acquired at 8:12am
Did you know?
Restek offers supplies and inno-
vative tools for yourMS. Refer to
the Instrument Supplies section
of the annual
Chromatography
Products Guide
(lit. cat.# 59473).
1...,181,182,183,184,185,186,187,188,189,190 192,193,194,195,196,197,198,199,200,201,...297
Powered by FlippingBook