Table of Contents Table of Contents
Previous Page  344 / 413 Next Page
Information
Show Menu
Previous Page 344 / 413 Next Page
Page Background

Figure 3

An amine modifier improves peak shape and changes

selecti vity fo r SSRls on an Allure" Basix column.

Peak List:

Ret Time

(min.)

Asymmetry Selectivity

«(X)

1.17

1.15

1.73

1.22

1.15

l. uracil

2. impurity

3. fluvoxamine maleate

3.754

4. lIuoxetine

5.553

5. sertralineHCI

6.222

U \.

"

I i

II, ii,II I"" I

I '" ''1'' '' '

illi

" " ,ii 'l

" "\ ii

I" """

1" " 1111

1.0

2.0

3.0

4~

~

M

~

U

U

M~

lCPH0354

sample:

Inj.:

lOpL

Cone.:

100pg/mL

each component

Sample diluent: water:acetonitnle, 50:50

Column:

Dimensions:

Particle size:

Pore size:

Conditions:

Mobile phase:

Flow:

Temp.:

Det.:

Allure~

Basix (cat.# 9161565)

150 x 4.6 mm

5!J~

60A

1%triethylamine in water (pH 6):acetonitrile, 50:50

I mUmin.

30°C

UV@23 0 nm

shape in reversed phase mod e. However, amine

additives work by blocking ioni zable silanols,

which can vary from column to column, so be sure

the amine concentration is high enough to sup­

press all potential silanol effects.

The Ultra PFP phase shows the best performance

at an acidic pH (Figure 4).

These analyses reveal that polar stationary phases

can effectively replace IPC in ana lyses of SSRls.

Overall, in RPC, polar stationary phases provide

better peak shape than alkyl ph ases for basic ana­

Iytes. When analyzing SSRls at neutral pH , the

Allure?" Basix phase is a good choice. When ana­

lyzing SSRls at an acidic pH , the Ultra PFP phase

is the better candidate.

Allure™ Basix Column

5J.tm

Column, 4.6mm

150mm

cal

#

9161565

Ultra PFP Column

5J.tm

Column, 4.6mm

150mm

cat.

#

9176565

ordering note

To order a 2.1mm, 3.2mm, or 4.6mm

ID

column with a

Trident"

I ntegral Inlet Fitting, add

"-700"

to the catalog number for the

column.

Nominal additional charge

For guard cartridges and XG-XF guard cartridge fittings for these

Figure

4

An Ultra PFP column shows good performance at acid ic pH.

columns, visit our website at

www.restek.com.

Ret. Time

Peak List:

(min.)

Asymmetry selectivity

«(X)

l. uracil

2. impurity

3. fluvoxamine maleate

6.291

l.02

4. sertraline HCI

8.030

1.10

1.39

5. fluoxetine

9.142

l.01

1.17

sample:

Inj.:

10!JL

Cone.:

100!Jg/ mL

each component

Sample diluent: water:acetonitrile, 50:50

Column:

Ultra PFP (cat.# 9176565)

Dimensions:

150 x 4.6mm

Particle size:

5!Jm

Pore size:

100A

Conditions:

Mobilephase: 20mM potassiumphosphate monobasic in water (pH3):acetonitrile,70:30

Flow:

I mL/min.

Temp.:

30°C

Det.:

UV @ 230 nm

2006

vol. 1

• 11 •

Website :

www.chromtech.net.au

E-mail :

info@chromatech.net.au

TelNo : 03 9762 2034 . . . in AUSTRALIA