Table of Contents Table of Contents
Previous Page  246 / 413 Next Page
Information
Show Menu
Previous Page 246 / 413 Next Page
Page Background

16

Air Monitoring

Performance Testing VOC

Audit Sample for Air Toxics

By Irene DeGraff, Product Marketing Manager

• Demonstrate your lab’s competence and compare anonymously to competitors.

• Improve your quality program.

• Applicable to US EPA, ASTM, and DIN EN ISO methods.

Restek is pleased to be a source of Performance Testing/VOC Audit Samples for

the Spectra Gases testing program. This is an on-going testing program in which

laboratories, or other users of VOC gas standards, are able to evaluate their own

capabilities and compare their performance with that of other air toxic labs. US

EPA methods TO-14A, TO-15, and TO-17 are used to determine volatile organic

compounds in ambient air. Without an air analysis accreditation program available, a

performance testing program by Spectra Gases provides an invaluable tool allowing labs to

demonstrate their competence with these methods.

As a participant in the program, you will receive a disposable cylinder directly from Spectra Gases

containing multiple unknown VOC components at varying concentrations that are to be identi-

fied, quantified, and reported via the Spectra Gases PT Audit Program form. The results will

then be published and distributed for peer review. The report provided to participants includes

a program methodology overview, compound list with actual concentration, and individual

and summary results for each compound (Figure 1). To ensure confidentiality, all participating

laboratories will be anonymous and only the individual laboratory will know their own results.

The audit sample will be shipped to all labs during the same period, once a year during the

fourth quarter. Analytical results need to be returned to Spectra Gases by January 30 to be included

in this statistical report.

Figure 1

Example graph from program report lets you

anonymously compare your lab to competitors.

Datapack not available.

TO-14A/TO-15/TO-17

Performance Test Standard

170 liters @ 2,015psi

cat. # 34560

(ea.) $950

TO-14A/TO-15/TO-17 Peformance Test Standard:

Size: 5A disposable (3.2" x 12")

Volume/Pressure: 170L @ 2,015psi

CGA 180 outlet fitting

Weight: 2.2lbs.

cylinder

design

Don’t miss out on this opportunity to confirm your competence in air toxic analysis—

order now to participate!

Benzene [71-43-2] 2.6ppb +/- 20%

Average = 3.06 Std. Dev. = 0.78