Table of Contents Table of Contents
Previous Page  105 / 413 Next Page
Information
Show Menu
Previous Page 105 / 413 Next Page
Page Background

UltraLine UHPLC In-Line Filter

Description

qty.

cat.#

UltraLine UHPLC In-Line Filter

(In-Line Assembly with Filter)

ea.

24993

UltraLine Replacement Filters 5-pk.

24994

UltraShield UHPLC PreColumn Filter

NEW!

• Cost-effective protection for UHPLC systems.

• Reliable way to extend column lifetime.

• Leak-tight to 15,000 psi.

UHPLC Filters

www.restek.com

15

Figure 1:

Restek columns offer the widest range of unique and effective column chemistries to aid the

chromatographer in fast and easy method development.

Restek phase

(column class)

Aqueous C18

(alkyl)

IBD

(polar embedded)

Biphenyl

(phenyl)

PFP Propyl

(fluorophenyl)

Ligand type

Proprietary polar modified

and functionally bonded C18

Proprietary polar functional

embedded alkyl

Unique Biphenyl

Proprietary end-capped

pentafluorophenyl propyl

Characteristics

and uses

• C18 phase for balanced

retention of multiple solute

types.

• Compatible with up to

100% aqueous mobile

phases.

• Enhanced retention of

polar acids.

• Moderate retention of

both acidic and basic

solutes.

• Increased retention of

aromatic, unsaturated,

conjugated solutes, or

solutes containing an

electron withdrawing

ring substituent.

• Enhanced retention and

selectivity when used with

methanolic mobile phases.

• Increased retention of

protonated bases and

solutes containing

aromatic moieties.

Si

OO

P

Si

CH

3

CH

3

O

Si

CH

3

CH

3

O

F

F

F

F

F

USLC™ Columns: Selectivity Choices Optimize Separations

Restek USLC™ columns, available in both HPLC and UHPLC formats, offer the widest range

of selectivities available and are an integral part of successful method development. Ideal

for column switching systems, these columns provide the orthogonal separations needed

to create optimal resolution and robust methods. Combining USLC™ phases with a suitable

column format gives practicing chromatographers the most powerful tool available for suc-

cessful method development.

Figure 2

Restek has extended the selectivity range for reversed phase separa-

tions as illustrated by the hydrophobic-subtraction model and corresponding

selectivity (S) value.

References

1. L.R. Snyder, J.W. Dolan, P.W. Carr, J. Chromatogr. A 1060 (2004) 77.

2. U.D. Neue, J.E O’Gara, A. Mendez, J. Chromatogr. A 1127 (2006) 161.

We’re here to help!

To discuss the right selectivity

for your separation or to find a

comparable column,

contact

us at

support@restek.com

or 800-356-1688.

Description

qty.

cat.#

UltraShield UHPLC

ea.

24995

PreColumn Filter

5-pk.

24996

10-pk.

24997

CH

3

CH

3

O

Si

P

Website :

www.chromtech.net.au

E-mail :

info@chromtech.net.au

TelNo : 03 9762 2034 . . . in AUSTRALIA