![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0296.jpg)
•
22
•
800-356-1688 •
www.restek.com2005 vol. 3
Simplify Your Analyses for Volatile Organic Compounds
by Donna Lidgett, GC Accessories Product Marketing Manager
nstrument nnovations
!
!
!
Purge-and-Trap Spargers for Tekmar 2000, 3000, or 3100 GCs
• Available with uniform frits, to ensure maximum purging efficiency.
• Use non-fritted spargers for wastewater samples.
• Manufactured to tight tolerances to ensure a leak-tight seal.
Description
qty.
cat.#
Fritted Spargers,
1
/
2
-inch mount
5mL Fritted Sparger
ea.
21150
10mL Fritted Sparger
ea.
26138
25mL Fritted Sparger
ea.
21151
Non-Fritted Spargers,
1
/
2
-inch mount
5mL Non-Fritted Sparger
ea.
26139
10mL Non-Fritted Sparger
ea.
26140
25mL Non-Fritted Sparger
ea.
26141
Moisture Control By-Pass Lines for Tekmar Instruments
• Increase response for ketones, alcohols, and acetates.
• Silcosteel®-deactivated tubing for increased inertness.
• Suitable for US EPA Methods 8260, 524.2, and OLM4.1.
• Easily attaches in minutes.
Description
qty.
cat.#
Moisture Control By-Pass Line for Tekmar 3000 Purge & Trap
ea.
21035
Moisture Control By-Pass Line for Tekmar 3100 Purge & Trap
ea.
21109
To replace these instrument part numbers:
Order these
Restek part numbers:
ELCD Model # Tremetrics
Varian
PerkinElmer
Shimadzu
O.I. Analytical
qty.
cat.#
Hall 700A
115439-0003
00-996724-14
0330-2675
—
— 2-pk.
21580
Hall 1000
117459-0003
00-997625-12
N660-1072
220-90435-00
— 2-pk.
21581
O.I. 4420
—
—
—
—
260323
2-pk.
21582
Cleaned Teflon® Transfer Lines for ELCDs
We stringently clean our ELCD Teflon® transfer lines with an HCl solution to remove any contaminants,
then rinse with methanol. Convenient 6.5-inch precut pieces that directly interface the nickel reaction
tube and conductivity cell in Tracor, Tremetrics, O.I., and many other ELCDs.
Description
qty.
cat.#
Teflon
®
Transfer Lines for ELCDs (five 6.5-inch lines)
5-pk.
20121
ELCD Nickel Reaction Tubes
• Pretreated for maximum sensitivity.
• Quality-controlled for reliability.
• Available for many popular models.
Replacement Accesories for Hall 1000
ELCD Nickel Reaction Tube Nut
High-quality stainless steel ELCD nut mounts nickel reaction tube into ELCD.
Description
qty.
cat.#
ELCD Nickel Reaction Tube Nut
2-pk.
21584
1
/
16
-Inch Vespel®/Graphite Sealing Ring
Installs onto the nickel reaction tube after the screw. Easily compresses on the reaction tube to provide a
leak-tight seal and prevent detector oxidation.
Description
qty.
cat.#
1
/
16
-Inch Vespel
®
/Graphite Sealing Ring
2-pk.
21583
new
for 2005